Combined measurement of ferritin, soluble transferrin receptor, retinol binding protein, and C-reactive protein by an inexpensive, sensitive, and simple sandwich enzyme-linked immunosorbent assay technique

被引:455
作者
Erhardt, JG
Estes, JE
Pfeiffer, CM
Biesalski, HK
Craft, NE
机构
[1] Univ Indonesia, Reg Ctr Community Nutr, SEAMEO, Jakarta 10430, Indonesia
[2] Craft Technol Inc, Wilson, NC 27893 USA
[3] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
[4] Univ Hohenheim, Inst Biol Chem & Nutr, D-70599 Stuttgart, Germany
关键词
ELISA; iron deficiency; vitamin A deficiency; low-cost method; infectious status;
D O I
10.1093/jn/134.11.3127
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The measurement of vitamin A (VA) and iron status is very important in the assessment of nutritional deficiencies. The objective of this research was to develop a sandwich ELISA technique for the simultaneous measurement of ferritin, soluble transferrin receptor, retinol binding protein, and C-reactive protein (CRP) as indicators for VA and iron status. The inclusion of CRP as marker of infection allows for more accurate interpretation of VA and iron status. This is accomplished in a 30-muL serum or plasma sample using an ELISA with different capture and detection antibodies and different dilutions of the sample. Commercially available clinical serum controls were used for calibration purposes. The developed assays were compared to commercially available traditional tests. Regression coefficients comparing both assays were better than 0.84 (P < 0.001). Using a limited sample set, the sandwich ELISA assay produced very similar specificity and sensitivity compared to traditional methods when common cutoff values were applied. Intra- and interassay variability was between 5 and 14% for all tests. The cost of the materials for all 5 measurements decreases to less than $1/sample if a large number of samples is analyzed. Due to the low cost, high throughput, and comparability to traditional tests, this procedure has several advantages for assessing VA and iron status in population surveys.
引用
收藏
页码:3127 / 3132
页数:6
相关论文
共 10 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Hyporetinolemia, illness symptoms, and acute phase protein response in pregnant women with and without night blindness
    Christian, P
    Schulze, K
    Stoltzfus, RJ
    West, KP
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 67 (06) : 1237 - 1243
  • [3] The quantitative assessment of body iron
    Cook, JD
    Flowers, CH
    Skikne, BS
    [J]. BLOOD, 2003, 101 (09) : 3359 - 3364
  • [4] Gamble MV, 2001, AM J CLIN NUTR, V73, P594
  • [5] Effects of subclinical infection on plasma retinol concentrations and assessment of prevalence of vitamin A deficiency: meta-analysis
    Thurnham, DI
    McCabe, GP
    Northrop-Clewes, CA
    Nestel, P
    [J]. LANCET, 2003, 362 (9401) : 2052 - 2058
  • [6] Tomkins A, 2003, J NUTR, V133, p1649S, DOI 10.1093/jn/133.5.1649S
  • [7] The contribution of vitamin A to public health
    Underwood, BA
    Arthur, P
    [J]. FASEB JOURNAL, 1996, 10 (09) : 1040 - 1048
  • [8] WHO UNICEF UNU, 1998, Iron Deficiency Anemia: Prevention, Assessment and control-Report of a Joint WHO/UNICEF/UNU Consultation
  • [9] Estimation of the effect of the acute phase response on indicators of micronutrient status in Indonesian infants
    Wieringa, FT
    Dijkhuizen, MA
    West, CE
    Northrop-Clewes, CA
    Muhilal
    [J]. JOURNAL OF NUTRITION, 2002, 132 (10) : 3061 - 3066
  • [10] World Health Organization, 1994, IND ASS VIT A DEF TH