Accuracy of whole-body 18F-FDP-PET for restaging malignant lymphoma

被引:16
作者
Mikosch, P
Gallowitsch, HJ
Zinke-Cerwenka, W
Heinisch, M
Pipam, W
Eibl, M
Kresnik, E
Unterweger, O
Linkesch, W
Lind, P
机构
[1] Hosp Klagenfurt, PET Ctr, Dept Nucl Med & Special Endocrinol, A-9020 Kalgenfurt, Austria
[2] Karl Franzens Univ Graz, Dept Internal Med, Div Haematol, Graz, Austria
关键词
positron emission tomography; fluorine-18-fluorodeoxyglucose; Hodgkin's disease; non-Hodgkin lymphoma; restaging;
D O I
10.1046/j.1563-2571.2003.03003.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this retrospective study was to evaluate the accuracy of fluorine-18 fluorodeoxyglucose positron emission tomography (F-18-FDG-PET) images, which were interpreted under daily routine conditions, in patients with Hodgkin's disease (HD) or non-Hodgkin lymphoma (NHL) for restaging after chemotherapy and/or radiotherapy. For this purpose, F-18-FDG-PET results were compared with morphological imaging methods and the patients' clinical background. Methods: 121 PET images of 93 lymphoma patients (44 HD, 49 NHL) were investigated after chemotherapy/radiotherapy. For PET imaging, 160-200 MBq F-18-FDG was administered intravenously, followed by an infusion of 20 mg Furosemid in 250 mL saline. Whole-body F-18-FDG-PET images were obtained using a partial-ring PET scanner without attenuation correction. The morphological imaging consisted in computed tomography and ultrasound (CT/US) in all patients, additional MRI in some patients, and iliac crest biopsy in cases of suspicious bone marrow involvement. The standard of reference was composed of biopsy data, clinical status at the time of investigation, and follow-up of at least 12 months. The PET images were evaluated for their sensitivity, specificity and accuracy based on written reports, which were compiled from other imaging data and the clinical history of the patients. Results: Sensitivity, specificity, and accuracy of (18) F-FDG-PET was 91 %, 81 %, and 85 %; of CT/US, 88 %, 35 %, 56 %, respectively. Major sources of error in F-18-FDG-PET were due to asymmetric muscular hypermetabolism and inflammatory lesions misinterpreted as persistent viable lymphoma tissue. Furthermore, secondary malignancies other than lymphomas were another reason for misinterpretations of F-18-FDG-PET studies. Conclusions: F-18-FDG-PET showed a comparable sensitivity but a higher specificity and accuracy compared with CT/US. To achieve a high accuracy in F-18-FDG-PET, the nuclear medicine specialist needs imaging and clinical data as background information, which can only be acquired through close co-operation with the referring clinicians. Pharmacological muscular relaxation in the course of F-18-FDG-PET imaging may be advisable, as nonspecific muscular hypermetabolism was one of the problems at the image readings and a source of incorrect F-18-FDG-PET interpretations.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 23 条
[1]  
ADAMS S, 2000, NUKLEARMEDIZIN, V39, P83
[2]  
Bangerter M, 1999, ACTA ONCOL, V38, P799
[3]   Detection of lymphoma in bone marrow by whole-body positron emission tomography [J].
Carr, R ;
Barrington, SF ;
Madan, B ;
O'Doherty, MJ ;
Saunders, CAB ;
van der Walt, J ;
Timothy, AR .
BLOOD, 1998, 91 (09) :3340-3346
[4]  
Cremerius U, 1999, NUKLEARMED, V38, P24
[5]   Positron emission tomography with 18F-FDG to detect residual disease after therapy for malignant lymphoma [J].
Cremerius, U ;
Fabry, U ;
Neuerburg, J ;
Zimny, M ;
Osieka, R ;
Buell, U .
NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (11) :1055-1063
[6]  
Delbeke D, 1999, J NUCL MED, V40, P591
[7]   Whole-body positron emission tomography (PET) for diagnosis of residual mass in patients with lymphoma [J].
deWit, M ;
Bumann, D ;
Beyer, W ;
Herbst, K ;
Clausen, M ;
Hossfeld, DK .
ANNALS OF ONCOLOGY, 1997, 8 :57-60
[8]  
Hoh CK, 1997, J NUCL MED, V38, P343
[9]   Accumulation of FDG in axillary sweat glands in hyperhidrosis: a pitfall in whole-body PET examination [J].
Jacobsson, H ;
Celsing, F ;
Ingvar, M ;
Stone-Elander, S ;
Larsson, SA .
EUROPEAN RADIOLOGY, 1998, 8 (03) :482-483
[10]   Whole-body positron emission tomography using 18F-fluorodeoxyglucose for posttreatment evaluation in Hodgkin's disease and non-Hodgkin's lymphoma has higher diagnostic and prognostic value than classical computed tomography scan imaging [J].
Jerusalem, G ;
Beguin, Y ;
Fassotte, MF ;
Najjar, F ;
Paulus, P ;
Rigo, P ;
Fillet, G .
BLOOD, 1999, 94 (02) :429-433