Characterization of unifocal liver lesions with pulse inversion harmonic imaging after Levovist injection: preliminary results

被引:64
作者
Bertolotto, M [1 ]
Dalla Palma, L [1 ]
Quaia, E [1 ]
Locatelli, M [1 ]
机构
[1] Univ Trieste, Ist Radiol, Osped Cattinara, I-34149 Trieste, Italy
关键词
liver; tumours; ultrasound; contrast media; pulse inversion harmonic imaging;
D O I
10.1007/s003300000497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate capabilities of pulse inversion harmonic imaging (PIHI) in characterization of unifocal liver lesions. We evaluated with PIHI (HDI5000, ATL, Bothell, Wash.) and spiral CT 46 consecutive patients with a single liver lesion identified by fundamental US [7 hepatocelluar carcinomas (HCC), 2 cholangiocarcinomas, 7 focal nodular hyperplasias (FNH), 17 hemangiomas and 13 metastases]. The PIHI was performed before and 30 s, 2 and 4 min after bolus administration of Levovist (2.5 g, 300 mg/ml). Scans were digitally red and reviewed using a dedicated software. Hepatocellular carcinoma was hyperechoic on 30-s sin, and hypoechoic (n = 5) or isoechoic (n = 2) on min scan. Cholangiocarcinoma had inhomogeneous persistent enhancement. Focal nodular hyperplasia was hyperechoic (n = 5) or isoechoic (n = 2) on 30-s scan, hyperechoic (n = 4), isoechoic (n = 2) or slightly hypoechoic (n = 1) on 2-min scan. Large hemangioma revealed peripheral enhancement on 30-s scan which extended centripetally on 2-min scan. Small hemangioma appeared isoechoic on 2-min scan in all,ut two cases in which they were hypoechoic on 2-min scans and hyperechoic on 4-min scan. Metastasis was hypoechoic on all scans, 70 % with rim enhancement. Similar changes in enhancement pattern have been observed at spiral CT. The 30-s and the 2-min scans revealed a conclusive importance in characterization of HCC, cholangio-carcinoma, and large hemangioma. The 2-min scan often furnished enough information for characterization of small hemangioma and metastasis. The 4-min :an allowed characterization of two hemangiomas which appeared hypoechoic on 2-min scans. In the other cases it did not provide further information. Diagnosis of FNH is usually reached with Colour Doper US; PIHI should be used when colour Doppler biased by artefacts or when colour Doppler findings are not characteristic. Our results seem to show that PIHI could be a valuable alternative diagnostic approach to spiral CT for unifocal liver lesion characterization. This hypothesis needs to be confirmed an increased number of lesions.
引用
收藏
页码:1369 / 1376
页数:14
相关论文
共 25 条
[1]  
Albrecht T, 1999, RADIOLOGY, V213P, P488
[2]   Liver-specific imaging with SHU 563A: Diagnostic potential of a new class of ultrasound contrast media [J].
Bauer, A ;
Blomley, M ;
Leen, E ;
Cosgrove, D ;
Schlief, R .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S349-S352
[3]  
BAUER A, 1997, ADV ECHO IMAGING USI, P669
[4]  
Blomley MJ, 1999, RADIOLOGY, V213P, P489
[5]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[6]   From the archives of the AFIP [J].
Buetow, PC ;
PantongragBrown, L ;
Buck, JL ;
Ros, PR ;
Goodman, ZD .
RADIOGRAPHICS, 1996, 16 (02) :369-388
[7]   Detection and characterization of hepatocellular carcinoma: Value of dynamic CT during the arterial dominant phase with uniphasic contrast medium injection [J].
Cho, JS ;
Kwag, JG ;
Oh, YR ;
Han, SD ;
Song, CJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) :128-134
[8]   Detection of liver metastases with pulse inversion harmonic imaging: Preliminary results [J].
Dalla-Palma, L ;
Bertolotto, M ;
Quaia, E ;
Locatelli, M .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S382-S387
[9]  
FOBBE F, 1992, RADIOLOGE, V32, P207
[10]   COLOR DOPPLER SONOGRAPHY OF HEPATIC-TUMORS WITH A GALACTOSE-BASED CONTRAST AGENT - CORRELATION WITH ANGIOGRAPHIC FINDINGS [J].
FUJIMOTO, M ;
MORIYASU, F ;
NISHIKAWA, K ;
NADA, T ;
OKUMA, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1099-1104