Active flexure compensation software for the Echellette Spectrograph and Imager on Keck II

被引:4
作者
Kibrick, R [1 ]
Miller, J [1 ]
Nelson, J [1 ]
Radovan, M [1 ]
Sheinis, A [1 ]
Sutin, B [1 ]
机构
[1] Univ Calif Santa Cruz, Univ Calif Observ, Lick Observ, Santa Cruz, CA 95064 USA
来源
ADVANCED TELESCOPE AND INSTRUMENTATION CONTROL SOFTWARE | 2000年 / 4009卷
关键词
active flexure compensation; Cassegrain spectrographs;
D O I
10.1117/12.388396
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
All Cassegrain spectrographs suffer from gravitationally-induced flexure to some degree. While such flexure can be minimized via careful attention to mechanical design and fabrication, further performance improvements can be achieved if the spectrograph has been designed to minimize hysteresis and has active compensation for any residual flexure. The Echellette Spectrograph and Imager (ESI), built at UCO/Lick Observatory for use at Cassegrain focus on Keck II: compensates for such residual flexure via its collimator mirror. The collimator is driven by three actuators that provide control of collimator focus, tip, and tilt. The ESI control software utilizes a mathematical model of gravitationally-induced flexure to periodically compute and apply flexure corrections by commanding the corresponding tip and tilt motions to the collimator. In addition, the ESI control software provides an optional, manual, closed-loop method for adjusting the collimator position to compensate for any non-repeatable errors. Such errors may result from mechanical hysteresis or from thermally-induced structural deformations of the instrument and are thus not accounted for by the gravitational flexure model. This method relies on measuring the centroid position of fiducial spots within each echellette image. The collimator is adjusted so that the positions of these spots match those in a reference image. These spots are produced by a small round hole in the slit mask located near one end of the slit. We discuss the design and calibration of this flexure compensation system and report on its performance on the telescope.
引用
收藏
页码:262 / 273
页数:12
相关论文
共 15 条
[1]   Determinate space-frame structure for the Keck II Echellette spectrograph and imager (ESI) [J].
Bigelow, BC ;
Nelson, JE .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :164-174
[2]  
Clarke D, 1997, PROCEEDINGS OF THE FIFTH ANNUAL TCL/TK WORKSHOP, P9
[3]  
CONRAD AR, 1993, ASTR SOC P, V52, P203
[4]   Active compensation of flexure on the WHT ISIS spectrograph [J].
DArrigo, P ;
Diego, F ;
Walker, DD .
MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1996, 281 (02) :679-686
[5]   Echellette spectrograph and imager (ESI) for Keck Observatory [J].
Epps, HW ;
Miller, JS .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :48-58
[6]   User interface and control software for the HIRES image rotator on Keck-1 [J].
Kibrick, R ;
Conrad, A ;
Gathright, J ;
Tucker, D .
TELESCOPE CONTROL SYSTEMS II, 1997, 3112 :187-198
[7]  
KIBRIK R, 2000, P SPIE, V4011
[8]  
LUPTON W, 1994, P SOC PHOTO-OPT INS, V2199, P638, DOI 10.1117/12.176232
[9]   FLEXURES OF CONVENTIONAL CASSEGRAIN-FED SPECTROGRAPHS [J].
MUNARI, U ;
LATTANZI, MG .
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1992, 104 (672) :121-126
[10]   Image motion and flexure compensation of the FORS Spectrographs [J].
Nicklas, H ;
Bohnhardt, H ;
Furtig, W ;
Harke, R ;
Hess, A ;
Jurgens, P ;
Muschielok, B ;
Seifert, W ;
Stahl, O ;
Tarantik, K .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :93-104