The oversampling phasing method

被引:96
作者
Miao, J [1 ]
Kirz, J [1 ]
Sayre, D [1 ]
机构
[1] SUNY Stony Brook, Dept Phys & Astron, Stony Brook, NY 11794 USA
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2000年 / 56卷
关键词
D O I
10.1107/S0907444900008970
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sampling the diffraction pattern of a finite specimen more finely than the Nyquist frequency (the inverse of the size of the diffracting specimen) corresponds to surrounding the electron density of the specimen with a no-density region. When the no-density region is bigger than the electron-density region, sufficient information is recorded so that the phase information can be retrieved from the oversampled diffraction pattern, at least in principle. By employing an iterative algorithm, the phase information from the oversampled diffraction pattern of a micrometre-sized test specimen has been successfully retrieved. This method is believed to be able to open a door for high-resolution three-dimensional structure determination of complex and non-crystalline biological specimens, i.e. whole cells and sub-micrometre molecular clusters and micrometre-sized protein crystals. With the possible appearance in the future of X-ray free-electron lasers, it may become possible to image single molecules by recording diffraction patterns before radiation damage manifests itself.
引用
收藏
页码:1312 / 1315
页数:4
相关论文
共 13 条
[1]  
BATES RHT, 1982, OPTIK, V61, P247
[2]   USE OF NON-CRYSTALLOGRAPHIC SYMMETRY FOR PHASE DETERMINATION [J].
CROWTHER, RA .
ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL CRYSTALLOGRAPHY AND CRYSTAL CHEMISTRY, 1969, B 25 :2571-+
[3]   PHASE RETRIEVAL ALGORITHMS - A COMPARISON [J].
FIENUP, JR .
APPLIED OPTICS, 1982, 21 (15) :2758-2769
[4]  
Goedgebuer J. P., 1980, SPRINGER LECT NOTES, V112, P229
[5]   Introductory overview [J].
Johnson, LN ;
Blundell, TL .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :813-815
[6]   SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS [J].
KIRZ, J ;
JACOBSEN, C ;
HOWELLS, M .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) :33-130
[7]  
Maser J., 1998, XRAY MICROSCOPY SPEC, P35, DOI [10.1007/978- 3- 642-72106- 9_4, DOI 10.1007/978-3-642-72106-9_4]
[8]   Phase retrieval from the magnitude of the Fourier transforms of nonperiodic objects [J].
Miao, J ;
Sayre, D ;
Chapman, HN .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (06) :1662-1669
[9]  
MIAO J, 2000, IN PRESS ACTA CRYS A, V56
[10]   Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens [J].
Miao, JW ;
Charalambous, P ;
Kirz, J ;
Sayre, D .
NATURE, 1999, 400 (6742) :342-344