Real-time quantitative PCR for retrovirus-like particle quantification in CHO cell culture

被引:34
作者
de Wit, C
Fautz, C
Xu, Y
机构
[1] Genentech Inc, Dept Cell Culture & Fermentat R&D, S San Francisco, CA 94080 USA
[2] Genentech Inc, Dept Qual Control, S San Francisco, CA 94080 USA
关键词
D O I
10.1006/biol.2000.0250
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chinese hamster ovary (CHO) cells have been widely used to manufacture recombinant proteins intended for human therapeutic uses. Retrovirus-like particles, which are apparently defective and non-infectious, have been detected in all CHO cells by electron microscopy (EM), To assure viral safety of CHO cell-derived biologicals, quantification of retrovirus-like particles in production cell culture and demonstration of sufficient elimination of such retrovirus-like particles by the down-stream purification process are required for product market registration worldwide. EM, with a detection limit of 1 x 10(6) particles/ml, is the standard retrovirus-like particle quantification method. The whole process, which requires a large amount of sample (3-5 litres), is labour intensive, time consuming, expensive, and subject to significant assay variability In this paper, a novel real-time quantitative PCR assay (TaqMan assay) has been developed for the quantification of retrovirus-like particles. Each retrovirus particle contains two copies of the viral genomic particle RNA (pRNA) molecule. Therefore, quantification of retrovirus particles can be achieved by quantifying the pRNA copy number, i.e. every two copies of retroviral pRNA is equivalent to one retrovirus-like particle. The TaqMan assay takes advantage of the 5'-->3' exonuclease activity of Tao DNA polymerase and utilizes the PRISM(TM) 7700 Sequence Detection System of PE Applied Biosystems (Foster City, CA, U.S.A.)for automated pRNA quantification through a dual-labelled fluorogenic probe, The TaqMan quantification technique is highly comparable to the EM analysis. In addition, it offers significant advantages over the EM analysis, such as a higher sensitivity of less than 600 particles/ml, greater accuracy and reliability higher sample throughput, more flexibility and lower cost. Therefore, the TaqMan assay should be used as a substitute for EM analysis for retrovirus-like particle quantification in CHO cell-based production system. (C) 2000 The International Association for Biologicals.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 27 条
  • [1] ENDOGENOUS ORIGIN OF DEFECTIVE RETROVIRUS-LIKE PARTICLES FROM A RECOMBINANT CHINESE-HAMSTER OVARY CELL-LINE
    ANDERSON, KP
    LOW, MAL
    LIE, YS
    KELLER, GA
    DINOWITZ, M
    [J]. VIROLOGY, 1991, 181 (01) : 305 - 311
  • [2] PRESENCE AND TRANSCRIPTION OF INTRACISTERNAL A-PARTICLE-RELATED SEQUENCES IN CHO CELLS
    ANDERSON, KP
    LIE, YS
    LOW, MAL
    WILLIAMS, SR
    FENNIE, EH
    NGUYEN, TP
    WURM, FM
    [J]. JOURNAL OF VIROLOGY, 1990, 64 (05) : 2021 - 2032
  • [3] [Anonymous], 1998, INT C HARM TECHN REQ
  • [4] COLLEN D, 1984, J PHARMACOL EXP THER, V231, P146
  • [5] DINOWITZ M, 1992, DEV BIOLOGICALS, V76, P201
  • [6] ELBIEN AD, 1991, TRENDS BIOTECHNOL, V9, P346
  • [7] *FOOD DRUG ADM CTR, 1997, POINTS CONS MAN TEST
  • [8] A novel method for real time quantitative RT PCR
    Gibson, UEM
    Heid, CA
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 995 - 1001
  • [9] Real time quantitative PCR
    Heid, CA
    Stevens, J
    Livak, KJ
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 986 - 994
  • [10] ENHANCED PROLIFERATION OF ENDOGENOUS VIRUS IN CHINESE-HAMSTER CELLS ASSOCIATED WITH MICROTUBULES AND THE MITOTIC APPARATUS OF THE HOST-CELL
    HEINE, UI
    KRAMARSKY, B
    WENDEL, E
    SUSKIND, RG
    [J]. JOURNAL OF GENERAL VIROLOGY, 1979, 44 (JUL) : 45 - 55