A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings

被引:24
作者
Unal, N
Kanhai, JKK
Buijk, SLCE
Pompe, JC
Holland, WPJ
Gultuna, I
Ince, C
Saygin, B
Bruining, HA
机构
[1] Univ Rotterdam Hosp, Surg Intens Care Unit, NL-3000 CA Rotterdam, Netherlands
[2] Ankara Univ, Fac Med, Dept Anesthesiol & Reanimat, TR-06100 Ankara, Turkey
[3] Univ Rotterdam Hosp, Dept Anesthesiol, Rotterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Anesthesiol, NL-1012 WX Amsterdam, Netherlands
关键词
humidity; heat and moisture exchangers; mechanical ventilation; temperature; resistance;
D O I
10.1007/s001340050535
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The purpose of this study was to assess and compare the humidification, heating, and resistance properties of three commercially available heat-moisture exchangers (HMEs). To mimic clinical conditions, a previously validated, new realistic experimental setup and measurement protocol was used. Design: Prospective, comparative experimental study. Setting: Surgical Intensive Care Unit, University Hospital of Rotterdam. Materials: An experimental set-up consisting of a patient model, measurement systems, and ventilator and three different HME types. Interventions: The air flow, pressure in the ventilation circuit, pressure difference over the HME, and partial water vapour pressure and temperature at each side of the HMEs were measured. Measurements were repeated every 30 min during the first 2 h and every hour up to 24 h for each HME at six different ventilator settings. The mean inspiratory and maximum expiratory resistance, flow-weighted mean absolute humidity and temperature outputs, and humidification and heating efficiencies of HMEs were calculated. Measurements and results. The DarHygroster had the highest humidity output, temperature output, humidification efficiency, and heating efficiency values throughout the study (32.8 +/- 21. mg/l, 32.2 +/- 0.8 degrees C, 86.3 +/- 2.3 %, and 0.9 +/- 0.01%, respectively) in comparison to the Humid-Vent Filter (25.3 +/- 3.2 mg/l, 31.9 +/- 0.8 degrees C, 72.2 +/- 5.3 % 0.9 +/- 0.02 %, respectively) and the Pall Ultipor BB100 breathing circuit filter (23.4 +/- 3 mg/l, 25.3 +/- 0.7 degrees C, 68.8 +/- 5.9 %, 0.8 +/- 0.02%, respectively). The inspiratory and expiratory resistance of the HMEs remained below clinically acceptable maximum values (2.60 +/- 0.04 and 2.45 +/- 0.05 cmH(2)O/l per s, respectively). Conclusion: The Dar Hygroster filter was found to have the highest humidity and temperature output of all three HMEs, the Humid-Vent filter had a satisfactory humidity output only at low tidal volume flow rate and minute volume settings, whereas the Pall Ultipore BE 100 never achieved a sufficient humidity and temperature output.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 41 条
[1]   HUMIDIFICATION IN ANESTHESIA - REVIEW OF PRESENT SITUATION [J].
BOYS, JE ;
HOWELLS, TH .
BRITISH JOURNAL OF ANAESTHESIA, 1972, 44 (08) :879-+
[2]  
BURTON JDK, 1962, LANCET, V1, P235
[3]   HUMIDITY AND THE ANESTHETIZED PATIENT [J].
CHALON, J ;
PATEL, C ;
ALI, M ;
RAMANATHAN, S ;
CAPAN, L ;
TANG, CK ;
TURNDORF, H .
ANESTHESIOLOGY, 1979, 50 (03) :195-198
[4]  
CHALON J, 1984, ANESTH ANALG, V63, P566
[5]   ENDOTRACHEAL-TUBE OCCLUSION ASSOCIATED WITH THE USE OF HEAT AND MOISTURE EXCHANGERS IN THE INTENSIVE-CARE UNIT [J].
COHEN, IL ;
WEINBERG, PF ;
FEIN, IA ;
ROWINSKI, GS .
CRITICAL CARE MEDICINE, 1988, 16 (03) :277-279
[6]   EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS [J].
CONTI, G ;
DEBLASI, RA ;
ROCCO, M ;
PELAIA, P ;
ANTONELLI, M ;
BUFI, M ;
MATTIA, C ;
GASPARETTO, A .
INTENSIVE CARE MEDICINE, 1990, 16 (07) :441-443
[7]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[8]   EVOLUTION OF HEAT AND MOISTURE IN RESPIRATORY TRACT DURING ANESTHESIA WITH A NON-REBREATHING SYSTEM [J].
DERY, R .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1973, 20 (03) :296-309
[9]   LABORATORY EVALUATION OF HEAT AND MOISTURE EXCHANGERS - ASSESSMENT OF THE DRAFT INTERNATIONAL STANDARD (ISO/DIS 9360) IN PRACTICE [J].
ECKERBOM, B ;
LINDHOLM, CE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (04) :291-295
[10]   PERFORMANCE EVALUATION OF 6 HEAT AND MOISTURE EXCHANGERS ACCORDING TO THE DRAFT INTERNATIONAL STANDARD (ISO DIS-9360) [J].
ECKERBOM, B ;
LINDHOLM, CE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (05) :404-409