Comparative Evaluation of Five Culture Media with Triplex PCR Assay for Detection of Methicillin-Resistant Staphylococcus aureus

被引:8
作者
Al-Talib, Hassanain [1 ]
Yean, Chan Yean [1 ]
Al-Khateeb, Alyaa [2 ]
Singh, Kirnpal-Kaur Banga [1 ]
Hasan, Habsah [1 ]
Al-Jashamy, Karim [3 ]
Ravichandran, Manickam [4 ]
机构
[1] Univ Sains Malaysia, Sch Med Sci, Dept Med Microbiol & Parasitol, Kota Baharu 16150, Kelantan, Malaysia
[2] Univ Sains Malaysia, Sch Med Sci, Ctr Human Genome, Kota Baharu 16150, Kelantan, Malaysia
[3] Management & Sci Univ, Fac Hlth & Life Sci, Shah Alam, Malaysia
[4] AIMST Univ, Fac Sci Appl, Kedah, Malaysia
关键词
MANNITOL SALT AGAR; CHROMAGAR MRSA; DISK DIFFUSION; SURVEILLANCE CULTURES; OXACILLIN RESISTANCE; SELECTIVE MEDIUM; SCREENING MEDIUM; CEFOXITIN; SYSTEM; MECA;
D O I
10.1007/s00284-009-9567-8
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The emergence of methicillin-resistant Staphylococcus aureus (MRSA) is responsible for nosocomial and community-acquired infections. Hence, rapid and accurate laboratory diagnosis of MRSA is a vital constituent of control measures. The present study evaluated five different methods for the identification of MRSA. A total of 207 S. aureus clinical isolates that consisted of 89 MRSA and 118 methicillin-susceptible S. aureus (MSSA) strains confirmed by PCR were tested. MRSA strains were evaluated by five different methods: chromogenic MRSA agar (CMRSA), oxacillin resistance screening agar base (ORSAB), mannitol salt oxacillin agar (MSO), mannitol salt cefoxitin agar with two different concentrations of cefoxitin [4 mu g/ml (MSC-4) and 6 mu g/ml (MSC-6)]. The results of the different methods were compared to mecA PCR as the gold standard. MSC-6 showed only six false-positive MRSA in comparison with PCR. The sensitivities and specificities of MSC-6, MSC-4, MSO-4, ORSAB, and CMRSA were as follows: 98.9/94.9%, 100/83.1%, 89.9/87.3%, 97.8/96.6%, and 95.5/94.9%, respectively. In comparison with PCR, it was found that both MSC-6 and ORSAB were relatively the least expensive screening tests ($0.70 and $1.00, respectively). In conclusion, all methods were comparable, but MSC-6 was the least expensive medium for MRSA screening.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 31 条
[1]   A pentaplex PCR assay for the rapid detection of methicillin-resistant Staphylococcus aureus and Panton-Valentine Leucocidin [J].
Al-Talib, Hassanain ;
Yean, Chan Yean ;
Al-Khateeb, Alyaa ;
Hassan, Habsah ;
Singh, Kirnpal-Kaur Banga ;
Al-Jashamy, Karim ;
Ravichandran, Manickam .
BMC MICROBIOLOGY, 2009, 9
[2]   Evaluation of a novel medium for screening specimens from hospitalized patients to detect methicillin-resistant Staphylococcus aureus [J].
Blanc, DS ;
Wenger, A ;
Bille, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (08) :3499-3502
[3]   Comparison of BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR versus the CHROMagar MRSA assay for screening patients for the presence of MRSA strains [J].
Boyce, John M. ;
Havill, Nancy L. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) :350-351
[4]   Derivatives of a vancomycin-resistant Staphylococcus aureus strain isolated at Hershey Medical Center [J].
Bozdogan, B ;
Ednie, L ;
Credito, K ;
Kosowska, K ;
Appelbaum, PC .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2004, 48 (12) :4762-4765
[5]   Guidelines for the laboratory diagnosis and susceptibility testing of methicillin-resistant Staphylococcus aureus (MRSA) [J].
Brown, DFJ ;
Edwards, DI ;
Hawkey, PM ;
Morrison, D ;
Ridgway, GL ;
Towner, KJ ;
Wren, MWD .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2005, 56 (06) :1000-1018
[6]   Methicillin resistance in staphylococci: Molecular and biochemical basis and clinical implications [J].
Chambers, HF .
CLINICAL MICROBIOLOGY REVIEWS, 1997, 10 (04) :781-+
[7]  
Clinical and Laboratory Standards Institute, 2009, M02A10 CLIN LAB STAN, V29
[8]   Comparison of methods for the isolation of methicillin resistant Staphylococcus aureus [J].
Davies, S ;
Zadik, PM .
JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (03) :257-258
[9]   A COMPARISON OF PCR DETECTION OF MECA WITH OXACILLIN DISK SUSCEPTIBILITY TESTING IN DIFFERENT MEDIA AND SCEPTOR AUTOMATED SYSTEM FOR BOTH STAPHYLOCOCCUS AUREUS AND COAGULASE-NEGATIVE STAPHYLOCOCCI ISOLATES [J].
Ercis, S. ;
Sancak, B. ;
Hascelik, G. .
INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 26 (01) :21-24
[10]   Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus aureus (MRSA):: a disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-screen latex agglutination test [J].
Felten, A ;
Grandry, B ;
Lagrange, PH ;
Casin, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (08) :2766-2771