Development of an amperometric immunosensor based on TiO2 nanoparticles and gold nanoparticles

被引:38
作者
Shi, Yin-Tao [1 ]
Yuan, Ruo [1 ]
Chai, Ya-Qin [1 ]
He, Xiu-Lan [1 ]
机构
[1] SW Univ, Chongqing Key Lab Analyt Chem, Coll Chem & Chem Engn, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
amperometric immunosensor; CEA; gold nanoparticles; horseradish peroxidase; self-assembly; Titania nanoparticles;
D O I
10.1016/j.electacta.2006.10.031
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A highly hydrophilic, non-toxic and conductive TiO2 nanoparticles/gold nanoparticles bilayer films as immobilization matrix via self-assembly (SA) and deposition method was prepared on a gold electrode. Subsequently, positively charged horseradish peroxidase (HRP) was assembled onto the bilayer films, which provided an interface to assemble gold nanoparticles for immobilization of carcinoembryonic antibody (anti-CEA). Finally, HRP was used to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were applied to characterize the electrochemical properties of the SA process. The CVs reduction current of the immunosensor decreases linearly in two concentrations ranges of CEA from 0.3 to 10 ng/ml and from 10 to 80 ng/ml with a detection limit of 0.2 ng/ml in presence of 0.7 mM H2O2 in analyte solution. Effects of deposition time, pH of working buffer, temperature and incubation time were also explored for optimum analytical performance by using the amperometric method. Moreover, the proposed immunosensor exhibited good accuracy, high sensitivity, long-term stability and made it to determine CEA in serum samples with satisfactory results. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3518 / 3524
页数:7
相关论文
共 42 条
[1]   Self-contained microelectrochemical immunoassay for small volumes using mouse IgG as a model system [J].
Aguilar, ZP ;
Vandaveer, WR ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3321-3329
[2]   Perspectives on the physical chemistry of semiconductor nanocrystals [J].
Alivisatos, AP .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (31) :13226-13239
[3]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[4]   Assessing the apparent effective thickness of alkanethiol self-assembled monolayers in different concentrations of Fe(CN)63-/Fe(CN)64- by ac impedance spectroscopy [J].
Cui, XL ;
Jiang, DL ;
Diao, P ;
Li, JX ;
Tong, RT ;
Wang, XK .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 470 (01) :9-13
[5]   Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen [J].
Dai, Z ;
Yan, F ;
Hua, Y ;
Hu, XY ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) :13-20
[6]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[7]   Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode [J].
Darain, F ;
Park, SU ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :773-780
[8]   Clinical utility of biochemical markers in colorectal cancer: European Group on Tumour Markers (EGTM) guidelines [J].
Duffy, MJ ;
van Dalen, A ;
Haglund, C ;
Hansson, L ;
Klapdor, R ;
Lamerz, R ;
Nilsson, O ;
Sturgeon, C ;
Topolcan, O .
EUROPEAN JOURNAL OF CANCER, 2003, 39 (06) :718-727
[9]   Serum CA 125, carcinoembryonic antigen, and CA 19-9 as tumor markers in borderline ovarian tumors [J].
Engelen, MJA ;
de Bruijn, HWA ;
Hollema, H ;
ten Koor, KA ;
Willemse, PHB ;
Aalders, JG ;
van der Zee, AGJ .
GYNECOLOGIC ONCOLOGY, 2000, 78 (01) :16-20
[10]   COAGULATION OF COLLOIDAL GOLD [J].
ENUSTUN, BV ;
TURKEVICH, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1963, 85 (21) :3317-+