Real-time clinical alerting: effect of an automated paging system on response time to critical laboratory values-a randomised controlled trial

被引:36
作者
Etchells, E. [1 ,2 ]
Adhikari, N. K. J. [1 ,2 ,3 ]
Cheung, C. [1 ,2 ]
Fowler, R. [1 ,2 ,3 ]
Kiss, A. [1 ]
Quan, S. [4 ]
Sibbald, W. [1 ,2 ,3 ]
Wong, B. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
[3] Univ Toronto, Interdept Div Crit Care, Toronto, ON, Canada
[4] Univ Hlth Network, Toronto, ON, Canada
来源
QUALITY & SAFETY IN HEALTH CARE | 2010年 / 19卷 / 02期
关键词
PATIENT OUTCOMES; INSTITUTIONS;
D O I
10.1136/qshc.2008.028407
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background Timely and reliable communication of critical laboratory values is a Joint Commission National Patient Safety Goal. The objective was to evaluate the effect of an automated system for paging critical values directly to the responsible physician. Methods A randomised controlled trial on the general medicine clinical teaching units at an urban academic hospital was conducted from February to May 2006; the unit of randomisation was the critical laboratory value. The intervention was an automated paging system that sent the critical value directly to the responsible physician's pager. The control arm was usual care, which was a telephone call to the patient's ward by the laboratory technician. The primary outcome was response time, defined as the interval between acceptance of the critical value into the laboratory information system to the writing of an order on the patient's chart in response to the critical value. If the time of order was not documented, the time of administration of treatment was used to calculate response time. Results For primary analysis, 165 critical values were evaluated on 108 patients with full response time data. The median response time was 16 min (IQR 2-141) for the automated paging group and 39.5 min (IQR 7-104.5) for the usual care group (p = 0.33). Conclusions The automated paging system reduced the length of time physicians took to respond to critical laboratory values, but this difference was not statistically significant. Future reseach should evaluate the effects of alerts for conditions that currently do not generate a phone call and the addition of real-time decision support to the critical value alerts.
引用
收藏
页码:99 / 102
页数:4
相关论文
共 11 条
[1]   Effects of computerized clinical decision support systems on practitioner performance and patient outcomes - A systematic review [J].
Garg, AX ;
Adhikari, NKJ ;
McDonald, H ;
Rosas-Arellano, MP ;
Devereaux, PJ ;
Beyene, J ;
Sam, J ;
Haynes, RB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (10) :1223-1238
[2]  
Howanitz PJ, 2002, ARCH PATHOL LAB MED, V126, P663
[3]   Improving response to critical laboratory results with automation: Results of a randomized controlled trial [J].
Kuperman, GJ ;
Teich, JM ;
Tanasijevic, MJ ;
Ma'Luf, N ;
Rittenberg, E ;
Jha, A ;
Fiskio, J ;
Winkelman, J ;
Bates, DW .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1999, 6 (06) :512-522
[4]   How promptly are inpatients treated for critical laboratory results? [J].
Kuperman, GJ ;
Boyle, D ;
Jha, A ;
Rittenberg, E ;
Ma'Luf, N ;
Tanasijevic, MJ ;
Teich, JM ;
Winkelman, J ;
Bates, DW .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1998, 5 (01) :112-119
[5]  
Major K, 2002, AM SURGEON, V68, P1057
[6]  
*ONT ASS MED LAB, 2005, OAML PROT REP LAB TE
[7]   Management of severe hypokalemia in hospitalized patients -: A study of quality of care based on computerized databases [J].
Paltiel, O ;
Salakhov, E ;
Ronen, I ;
Berg, D ;
Israeli, A .
ARCHIVES OF INTERNAL MEDICINE, 2001, 161 (08) :1089-1095
[8]  
Park HI, 2008, ANN CLIN LAB SCI, V38, P149
[9]   Technology, work, and information flows: Lessons from the implementation of a wireless alert pager system [J].
Reddy, MC ;
McDonald, DW ;
Pratt, W ;
Shabot, MM .
JOURNAL OF BIOMEDICAL INFORMATICS, 2005, 38 (03) :229-238
[10]  
Shabot M Michael, 2004, Proc (Bayl Univ Med Cent), V17, P265