Small-scale concrete slab tests at ambient and elevated temperatures

被引:121
作者
Bailey, Colin G. [1 ]
Toh, Wee Siang [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester M60 1QD, Lancs, England
关键词
large displacements; concrete slabs; fire tests; membrane action; fracture of reinforcement;
D O I
10.1016/j.engstruct.2007.01.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents test results of forty-eight horizontally unrestrained two-way spanning reinforced concrete slabs at ambient and elevated temperatures. The tests allowed a direct comparison between the modes of failure observed at ambient and elevated temperatures. Both mild steel and stainless-steel welded smooth wire meshes, with varying bar diameters and spacing, were used as reinforcement. The tests at ambient temperature showed that slabs with low reinforcement ratio failed by fracture of reinforcement at the centre of the slab either across the shorter span for the rectangular slabs or across one of the spans for the square slabs. It was found that increasing the reinforcement ratio led to the compressive failure of concrete at the corners of the slabs. Repeating the tests at elevated temperatures showed that all the slabs failed by fracture of reinforcement, with displacements ranging from span/12 to span/6. The results showed clearly that membrane action occurred at both ambient and elevated temperatures, and provides a wealth of data which can be used to further develop simple design methods or validate existing finite-element models. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2775 / 2791
页数:17
相关论文
共 28 条
[1]  
Bailey C. G., 2000, STRUCT ENG, V78, P19
[2]   The tensile membrane action of unrestrained composite slabs simulated under fire conditions [J].
Bailey, CG ;
White, DS ;
Moore, DB .
ENGINEERING STRUCTURES, 2000, 22 (12) :1583-1595
[3]   Membrane action of slab/beam composite floor systems in fire [J].
Bailey, CG .
ENGINEERING STRUCTURES, 2004, 26 (12) :1691-1703
[4]   Efficient arrangement of reinforcement for membrane behaviour of composite floor slabs in fire conditions [J].
Bailey, CG .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (07) :931-949
[5]   Membrane action of unrestrained lightly reinforced concrete slabs at large displacements [J].
Bailey, CG .
ENGINEERING STRUCTURES, 2001, 23 (05) :470-483
[6]  
Bailey CG, 2001, STEEL STRUCTURES SUP
[7]  
BAKHT B, 1969, CONCRETE INT, V18, P50
[8]  
Cameron N.J.K., 2005, STRUCT ENG, V83, P28
[9]   Numerical modelling of the structural fire behaviour of composite buildings [J].
Elghazouli, AY ;
Izzuddin, BA ;
Richardson, AJ .
FIRE SAFETY JOURNAL, 2000, 35 (04) :279-297
[10]   Experimental behaviour of concrete floor slabs at large displacements [J].
Foster, SJ ;
Bailey, CG ;
Burgess, IW ;
Plank, RJ .
ENGINEERING STRUCTURES, 2004, 26 (09) :1231-1247