Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress comparison with 99mTc-Sestamibi SPECT imaging

被引:126
作者
Heinle, SK
Noblin, J
Goree-Best, P
Mello, A
Ravad, G
Mull, S
Mammen, P
Grayburn, PA
机构
[1] Vet Adm Med Ctr, Div Cardiol 111A, Dallas, TX 75216 USA
[2] Univ Texas, SW Med Ctr, Dept Internal Med, Div Cardiol, Dallas, TX USA
关键词
contrast media; echocardiography; perfusion; stress; tomography; adenosine;
D O I
10.1161/01.CIR.102.1.55
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by Tc-99m-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress, Methods and Results-HPDI was performed on 123 patients who were referred for SPECT imaging for known or suspected coronary artery disease. Images were obtained at baseline and during adenosine infusion (0.14 mg.kg(-1)min(-1)x6 minutes) in 3 apical views. Myocardial perfusion by HPDI was graded for each coronary territory as absent, patchy, or full. The persistence of absent or patchy myocardial perfusion by HPDI between rest and adenosine was interpreted as a fixed defect, whereas any decrease in perfusion grade was interpreted as a reversible defect. Overall concordance between HPDI and SPECT was 83 (81%) of 103 for normal versus abnormal perfusion. Agreement between the 3 methods for each of the 3 coronary territories was 81% (kappa=0.57) for the left anterior descending artery, 76% (kappa=0.52) for the right coronary artery, and 72% (kappa=0.40) for the left circumflex artery. Discrepancies between the 2 techniques were most notable in the circumflex territory, where fixed defects were observed in 33% by HPDI but in only 14% by SPECT (chi(2)=15.8, P=0.0001). Conclusions-This study demonstrates that HPDI can reliably detect myocardial perfusion during pharmacological stress, although there was a significantly higher number of falsely abnormal results in the circumflex territory.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 25 条
[1]  
AGARWAL DI, 1997, ECHOCARDIOGR-J CARD, V14, P631
[2]   Harmonic power Doppler contrast echocardiography:: Preliminary clinical results [J].
Becher, H ;
Tiemann, K ;
Schlief, R ;
Lüderitz, B ;
Nanda, NC .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (06) :637-642
[3]   Assessment of myocardial perfusion by intermittent harmonic power Doppler using SonoVue, a new ultrasound contrast agent [J].
Broillet, A ;
Puginier, J ;
Ventrone, R ;
Schneider, M .
INVESTIGATIVE RADIOLOGY, 1998, 33 (04) :209-215
[4]   Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent - Results of a phase III multicenter trial [J].
Cohen, JL ;
Cheirif, J ;
Segar, DS ;
Gillam, LD ;
Gottdiener, JS ;
Hausnerova, E ;
Bruns, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :746-752
[5]   Myocardial contrast echocardiography in the evaluation of viable myocardium after acute myocardial infarction [J].
Galiuto, L ;
Iliceto, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12A) :29G-32G
[6]  
GLANTZ SA, 1987, PRIMER BIOSTATISTICS, P277
[7]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[8]   Acoustically stimulated transient power scattering explains enhanced detection of the very low velocities in myocardial capillaries by power Doppler imaging: An in vitro study [J].
Irvine, T ;
Wanitkun, S ;
Powers, J ;
Shiota, T ;
Kenny, A ;
Sahn, DJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (08) :643-649
[9]   LACK OF MYOCARDIAL PERFUSION IMMEDIATELY AFTER SUCCESSFUL THROMBOLYSIS - A PREDICTOR OF POOR RECOVERY OF LEFT-VENTRICULAR FUNCTION IN ANTERIOR MYOCARDIAL-INFARCTION [J].
ITO, H ;
TOMOOKA, T ;
SAKAI, N ;
YU, H ;
HIGASHINO, Y ;
FUJII, K ;
MASUYAMA, T ;
KITABATAKE, A ;
MINAMINO, T .
CIRCULATION, 1992, 85 (05) :1699-1705
[10]   CLINICAL BIOSTATISTICS .54. THE BIOSTATISTICS OF CONCORDANCE [J].
KRAMER, MS ;
FEINSTEIN, AR .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (01) :111-123