Different stabilisation techniques for typical acetabular fractures in the elderly-A biomechanical assessment

被引:91
作者
Culemann, U. [1 ]
Holstein, J. H. [1 ]
Koehler, D. [1 ]
Tzioupis, C. C. [2 ]
Pizanis, A. [1 ]
Tosounidis, G. [1 ]
Burkhardt, M. [1 ]
Pohlemann, T. [1 ]
机构
[1] Univ Saarland, Dept Trauma Hand & Reconstruct Surg, D-66421 Homburg, Germany
[2] Univ Leeds, Sch Med, Leeds Gen Infirm, Acad Dept Trauma & Orthopaed Surg, Leeds LS2 9JT, W Yorkshire, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2010年 / 41卷 / 04期
关键词
Acetabular fracture; Biomechanics; Cadaveric pelvises; Synthetic pelvises; The elderly; INTERNAL-FIXATION;
D O I
10.1016/j.injury.2009.12.001
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Objectives: The tremendous increase of acetabular fractures in the elderly provides new challenges for their surgical treatment. The aim of this study was to evaluate the biomechanical properties of conventional and newly developed implants for the stabilisation of an anterior column combined with posterior hemitransverse fracture (ACPHTF), which represents the typical acetabular fracture in the elderly. Methods: Using a single-leg stance model we analysed four different implant systems for the stabilisation of ACPHTFs in synthetic and cadaveric pelvises. Applying an increasing axial load, fracture dislocation was analysed with a new multidirectional ultrasonic measuring system. Results of the different implant systems were compared by Scheffe post hoc test and one-way ANOVA. Results: In synthetic pelvises, the standard reconstruction plate fixed by 3 periarticular long screws and a new titanium fixator with multidirectional interlocking screws were associated with significantly less dislocation of the fractured quadrilateral plate of the acetabulum when compared to a standard reconstruction plate fixed by only one periarticular long screw and a locking reconstruction plate. No significant differences between the different osteosynthesis techniques could be observed in cadaver pelvises, probably due to a heterogeneous bone quality. Conclusions: We conclude that the plate fixation by positioning of periarticular long screws as well as the multidirectional positioning of interlocking screws account for the most sufficient fracture stabilisation of ACPHTFs under experimental conditions. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:405 / 410
页数:6
相关论文
共 28 条
[1]
The "Gull sign" - A harbinger of failure for internal fixation of geriatric acetabular fractures [J].
Anglen, JO ;
Burd, TA ;
Hendricks, KJ ;
Harrison, P .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (09) :625-634
[2]
BAUMGAERTEL F, 1992, ORTHOPADE, V21, P427
[3]
Crowl Adam C, 2002, Comput Aided Surg, V7, P169, DOI 10.1002/igs.10040
[4]
Culemann U, 2000, UNFALLCHIRURG, V103, P965, DOI 10.1007/s001130050654
[5]
Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[6]
Fenzl G, 1990, Unfallchirurgie, V16, P230, DOI 10.1007/BF02589875
[7]
Haas NP, 1999, ZBL CHIR, V124, P999
[8]
A biomechanical evaluation of mandibular condyle fracture plating techniques [J].
Haug, RH ;
Peterson, GP ;
Goltz, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (01) :73-80
[9]
HESP WLEM, 1988, ACTA CHIR BELG, V88, P27
[10]