The use of a closed-suction drain in total knee arthroplasty - A prospective, randomised study

被引:116
作者
Esler, CNA
Blakeway, C
Fiddian, NJ
机构
[1] Royla Bournemouth Hosp, Bournemouth, Dorset, England
[2] Christchurch Hosp, Bournemouth, Dorset, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2003年 / 85B卷 / 02期
关键词
D O I
10.1302/0301-620X.85B2.13357
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
W e prospectively randomised 100 patients undergoing cemented total knee replacement to receive either a single deep closed-suction drain or no drain. The total blood loss was significantly greater in those with a drain (568 ml versus 119 ml, p < 0.01; 95 % CI 360 to 520) although those without lost more blood into the dressings (55 ml versus 119 ml, p < 0.01; 95% CI -70 to 10). There was no statistical difference in the postoperative swelling or pain score, or in the incidence of pyrexia, ecchymosis, time at which flexion was regained or the need for manipulation, or in the incidence of infection at a minimum of five years after surgery in the two groups. We have been unable to provide evidence to support the use of a closed-suction drain in cemented knee arthroplasty. It merely interferes with mobilisation and complicates nursing. Reinfusion drains may, however, prove to be beneficial.
引用
收藏
页码:215 / 217
页数:3
相关论文
共 10 条
[1]  
Chandratreya A, 1998, J ROY COLL SURG EDIN, V43, P404
[2]  
DRINKWATER CJ, 1995, J ARTHROPLASTY, V10, P185, DOI 10.1016/S0883-5403(05)80125-1
[3]  
Holt BT, 1997, ORTHOPEDICS, V20, P1121
[4]  
Jenny JY, 2001, KNEE SURG SPORT TR A, V9, P299
[5]   PERIOPERATIVE BLOOD-LOSS ASSOCIATED WITH TOTAL KNEE ARTHROPLASTY - A COMPARISON OF PROCEDURES PERFORMED WITH AND WITHOUT CEMENTING [J].
MYLOD, AG ;
FRANCE, MP ;
MUSER, DE ;
PARSONS, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07) :1010-1012
[6]  
REILLY TJ, 1986, CLIN ORTHOP RELAT R, P238
[7]   CLOSED WOUND DRAINAGE IN TOTAL HIP OR TOTAL KNEE REPLACEMENT - A PROSPECTIVE RANDOMIZED STUDY [J].
RITTER, MA ;
KEATING, EM ;
FARIS, PM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (01) :35-38
[8]  
ROBERTSSON O, 2001, SWEDISH KNEE ARTHROP
[9]   SUCTION DRAINAGE OF ORTHOPAEDIC WOUNDS [J].
WAUGH, TR ;
STINCHFIELD, FE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (07) :939-&
[10]   THE EFFECT OF SUCTION DRAINS AFTER TOTAL HIP-REPLACEMENT [J].
WILLETT, KM ;
SIMMONS, CD ;
BENTLEY, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :607-610