Anatoxin-a degradation by Advanced Oxidation Processes: Vacuum-UV at 172 nm, photolysis using medium pressure UV and UV/H2O2

被引:62
作者
Afzal, Atefeh [1 ]
Oppenlaender, Thomas [2 ]
Bolton, James R. [1 ]
El-Din, Mohamed Gamal [1 ]
机构
[1] Univ Alberta, Markin CNRL Nat Resources Engn Facil 3 133, Edmonton, AB T6G 2W2, Canada
[2] Hsch Furtwangen Univ, Fac Mech & Proc Engn, D-78054 Villingen Schwenningen, Germany
基金
加拿大自然科学与工程研究理事会;
关键词
Anatoxin-a; Advanced Oxidation Processes; Vacuum-UV; Xenon excimer lamp; Photolysis; UV/H2O2; ELECTRICAL ENERGY EFFICIENCY; WATER-TREATMENT OPTIONS; CYANOBACTERIAL TOXINS; AQUEOUS-SOLUTION; ALGAL TOXINS; CYANOTOXINS; RADIOLYSIS; OZONATION; RADICALS; KINETICS;
D O I
10.1016/j.watres.2009.09.021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two Advanced Oxidation Processes, namely vacuum-ultraviolet (VUV) photolysis at 172 nm and ultraviolet/hydrogen peroxide (UV/H2O2) were investigated for the degradation of anatoxin-a in aqueous solutions. Solutions of anatoxin-a-fumarate were treated with VUV light at 172 nm with a UV dose of 200 mJ/cm(2), where fumaric acid served as a reference compound for a competition kinetics analysis. The second-order rate constant for the reaction between anatoxin-a and the hydroxyl radical was found to be (5.2 +/- 0.3) x 10(9) M-1 s(-1) and was independent of pH, temperature, and initial concentration of anatoxin-a. The direct photolysis of anatoxin-a using a medium pressure (MP) UV lamp was also investigated, in which case a UV dose of 1285 mJ/cm(2) was required to degrade anatoxin-a by 88% and 50% at concentrations of 0.6 mg/L and 1.8 mg/L of toxin, respectively. Treatment of anatoxin-a with a low pressure (LP) UV lamp in the presence of 30 mg/L of H2O2 was examined, where it was found that more than 70% of toxin could be degraded at a UV dose of 200 mJ/cm(2). The degradation arises from the oxidation of the toxin by hydroxyl radicals. The addition of H2O2 clearly enhanced the degradation of anatoxin-a, up to a concentration of 40 mg/L, after which addition of more H2O2 had little effect on the degradation kinetics of anatoxin-a. The effect of background constituents in the water on the degradation of anatoxin-a was also investigated using natural and synthetically produced model waters. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:278 / 286
页数:9
相关论文
共 29 条
[1]   Fundamental photochemical approach to the concepts of fluence (UV dose) and electrical energy efficiency in photochemical degradation reactions [J].
Bolton, JR ;
Stefan, MI .
RESEARCH ON CHEMICAL INTERMEDIATES, 2002, 28 (7-9) :857-870
[2]   Standardization of methods for fluence (UV dose) determination in bench-scale UV experiments [J].
Bolton, JR ;
Linden, KG .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2003, 129 (03) :209-215
[3]  
CABELLI DE, 1985, Z NATURFORSCH B, V40, P1731
[4]   CYANOBACTERIA SECONDARY METABOLITES - THE CYANOTOXINS [J].
CARMICHAEL, WW .
JOURNAL OF APPLIED BACTERIOLOGY, 1992, 72 (06) :445-459
[5]   Cyanobacterial (Blue-Green algal) toxins in water supplies: Cylindrospermopsins [J].
Falconer, Ian R. ;
Humpage, Andrew R. .
ENVIRONMENTAL TOXICOLOGY, 2006, 21 (04) :299-304
[6]   HIGH-INTENSITY RADIOLYSIS OF AQUEOUS FERROUS SULFATE-CUPRIC SULFATE-SULFURIC ACID SOLUTIONS [J].
FENG, PY ;
BRYNJOLF.A ;
HALLIDAY, JW ;
JARRETT, RD .
JOURNAL OF PHYSICAL CHEMISTRY, 1970, 74 (06) :1221-&
[7]  
Hall T, 2000, J CHART INST WATER E, V14, P143
[8]   ACID-BASE PROPERTIES OF ORGANIC PEROXY RADICALS, .OORH, IN AQUEOUS-SOLUTION [J].
HAYON, E ;
SIMIC, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1973, 95 (20) :6681-6684
[9]   Vacuum-UV (172 nm) actinometry. The quantum yield of the photolysis of water [J].
Heit, G ;
Neuner, A ;
Saugy, PY ;
Braun, AM .
JOURNAL OF PHYSICAL CHEMISTRY A, 1998, 102 (28) :5551-5561
[10]   Cyanobacterial toxins:: Removal during drinking water treatment, and human risk assessment [J].
Hitzfeld, BC ;
Höger, SJ ;
Dietrich, DR .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 :113-122