Routine use of mupirocin at the peritoneal mupirocin resistance: still low after 7 years

被引:44
作者
Lobbedez, T
Gardam, M
Dedier, H
Burdzy, D
Chu, M
Izatt, S
Bargman, JM
Jassal, SV
Vas, S
Brunton, J
Oreopoulos, DG
机构
[1] Univ Hlth Network, Div Nephrol, Toronto, ON, Canada
[2] Univ Hlth Network, Div Infect Prevent & Control, Toronto, ON, Canada
[3] Univ Hlth Network, Div Infect Dis, Toronto, ON, Canada
关键词
catheter exit site; mupirocin; resistance; Staphylococcus aureus; peritoneal dialysis;
D O I
10.1093/ndt/gfh494
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Objective. The purpose of this study (the third in a series of similar studies) is to evaluate the prevalence of Staphylococcus aureus (SA), methicillin-resistant SA (MRSA) and mupirocin-resistant SA (MuRSA) carriers in a peritoneal dialysis centre where patients have been instructed to use prophylactic mupirocin ointment at the catheter exit site over the last 7 years. Methods. Swabs were taken from catheter exit site, nares, axillae and groin in 147 chronic peritoneal dialysis out-patients between November 2003 and January 2004. Axillae/groin and nasal samples were pooled and cultured in the same medium, whereas exit site swabs were cultured separately. All SA isolated were tested for methicillin and mupirocin resistance using oxacillin screening plates and E-test strips. Results. Sixteen of 147 patients (10.9%) were found to be SA carriers: of these 13 (8.8%) had a positive nasal/axillae/groin culture; two (1.4%) had both nasal/axillae/groin- and exit site-positive culture; and one (0.7%) had only exit, site-positive culture. In these 16 SA carriers, we found mupirocin-resistant strains (MuRSA) in four patients (25%) and MRSA in two patients (12.5%). Among the four MuRSA carriers, one had both nasal/axillae/groin- and exit site-positive culture and three had only nasal/axillae/groin-positive culture. Three high-level resistance and one low-level resistance MuRSA carriers were isolated. One MuRSA strain was also methicillin resistant. All MRSA strains were sensitive to vancomycin and rifampicin. Conclusion. After 7 years' routine use of prophylactic mupirocin ointment at the catheter exit site in non-selected chronic peritoneal dialysis patients, MuRSA was found in 25% of SA strains isolated or in 2.7% of the patients. Compared with our previous study, 3 years earlier, there is no significant increase in the MuRSA prevalence in peritoneal dialysis patients who routinely apply mupirocin ointment at the catheter exit site.
引用
收藏
页码:3140 / 3143
页数:4
相关论文
共 21 条
[1]   Staphylococcal peritonitis in continuous ambulatory peritoneal dialysis:: Colonization with identical strains at exit site, nose, and hands [J].
Amato, D ;
Venture, MD ;
Miranda, G ;
Leaños, B ;
Alcántara, G ;
Hurtado, ME ;
Paniagua, R .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 37 (01) :43-48
[2]  
Annigeri R, 2001, PERITON DIALYSIS INT, V21, P554
[3]  
Casey M, 2000, PERITON DIALYSIS INT, V20, P566
[4]  
CAVDAR C, 2004, PERITON DIALYSIS INT, V24, pS33
[5]  
Conly JM, 2002, PERITON DIALYSIS INT, V22, P649
[6]   The emergence of mupirocin resistance: a challenge to infection control and antibiotic prescribing practice [J].
Cookson, BD .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1998, 41 (01) :11-18
[7]  
Crabtree J H, 2000, Adv Perit Dial, V16, P271
[8]  
DAVIES SJ, 1989, PERITON DIALYSIS INT, V9, P61
[9]  
FONTAN MP, 1992, ADV PERIT DIAL, V8, P242
[10]   Treatment of Staphylococcus aureus colonization and prophylaxis for infection with topical intranasal mupirocin:: An evidence-based review [J].
Laupland, KB ;
Conly, JM .
CLINICAL INFECTIOUS DISEASES, 2003, 37 (07) :933-938