Biosensors based on novel peroxidases with improved properties in direct and mediated electron transfer

被引:109
作者
Lindgren, A
Ruzgas, T
Gorton, L
Csöregi, E
Ardila, GB
Sakharov, IY
Gazaryan, IG
机构
[1] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[2] Lund Univ, Dept Biotechnol, SE-22100 Lund, Sweden
[3] Santander Ind Univ, Sch Chem, AA-678 Bucaramanga, Colombia
[4] Moscow MV Lomonosov State Univ, Fac Chem, Dept Chem Enzymol, Moscow 119899, Russia
关键词
plant peroxidases; direct electron transfer; mediated electron transfer; biosensor; enzyme kinetics; rate constants;
D O I
10.1016/S0956-5663(00)00110-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Native horseradish peroxidase (HRP) on graphite has revealed approximate to 50% of the active enzyme molecules to be in direct electron transfer (ET) contact with the electrode surface. Some novel plant peroxidases from tobacco, peanut and sweet potato were kinetically characterised on graphite in order to find promising candidates for biosensor applications and to understand the nature of the direct ET in the case of plant peroxidases. From measurements of the mediated and mediatorless currents of hydrogen peroxide reduction at the peroxidase-modified rotating disk electrodes (RDE), it was concluded that the fraction of enzyme molecules in direct ET varies substantially for the different plant peroxidases. It was observed that the anionic peroxidases (from sweet potato and tobacco) demonstrated a higher percentage of molecules in direct ET than the cationic ones (HRP and peanut peroxidase). The peroxidases with a high degree of glycosylation demonstrated a lower percentage of molecules in direct ET. It could, thus, be concluded that glycosylation of the peroxidases hinders direct ET and that a net negative charge on the peroxidase (low pi value) is beneficial for direct ET. Especially noticeable are the Values obtained for sweet potato peroxidase (SPP), revealing both a high percentage in direct ET and a high rate constant of direct ET. The peroxidase electrodes were used for determination of hydrogen peroxide in RDE mode (mediatorless). SPP gave the lowest detection limit (40 nM) followed by HRP and peanut peroxidase. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:491 / 497
页数:7
相关论文
共 29 条
[1]  
ANDRADE JD, 1986, ADV POLYM SCI, V79, P1
[2]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[3]   USE OF ENZYMES IN IMMUNOASSAY TECHNIQUES - A REVIEW [J].
BLAKE, C ;
GOULD, BJ .
ANALYST, 1984, 109 (05) :533-547
[4]   MOLECULAR-CLONING OF COMPLEMENTARY DNAS ENCODING 2 CATIONIC PEROXIDASES FROM CULTIVATED PEANUT CELLS [J].
BUFFARD, D ;
BREDA, C ;
VANHUYSTEE, RB ;
ASEMOTA, O ;
PIERRE, M ;
HA, DBD ;
ESNAULT, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (22) :8874-8878
[5]  
Dunford H. B., 1991, PEROXIDASES CHEM BIO, VII, P1
[6]   Crystal structure of horseradish peroxidase C at 2.15 angstrom resolution [J].
Gajhede, M ;
Schuller, DJ ;
Henriksen, A ;
Smith, AT ;
Poulos, TL .
NATURE STRUCTURAL BIOLOGY, 1997, 4 (12) :1032-1038
[7]   Purification and unusual kinetic properties of a tobacco anionic peroxidase [J].
Gazaryan, IG ;
Lagrimini, LM .
PHYTOCHEMISTRY, 1996, 41 (04) :1029-1034
[8]   Enzyme-catalyzed direct electron transfer: Fundamentals and analytical applications [J].
Ghindilis, AL ;
Atanasov, P ;
Wilkins, E .
ELECTROANALYSIS, 1997, 9 (09) :661-674
[9]   Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors [J].
Gorton, L ;
Lindgren, A ;
Larsson, T ;
Munteanu, FD ;
Ruzgas, T ;
Gazaryan, I .
ANALYTICA CHIMICA ACTA, 1999, 400 :91-108
[10]   BIOSYNTHESIS AND LOCALIZATION OF PEANUT PEROXIDASES - A COMPARISON OF THE CATIONIC AND THE ANIONIC ISOZYMES [J].
HU, CF ;
SMITH, R ;
VANHUYSTEE, R .
JOURNAL OF PLANT PHYSIOLOGY, 1989, 135 (04) :391-397