Gel microdroplet technique leaving microorganisms alive for sorting by flow cytometry

被引:16
作者
Katsuragi, T [1 ]
Tanaka, S [1 ]
Nagahiro, S [1 ]
Tani, Y [1 ]
机构
[1] Nara Inst Sci & Technol, Grad Sch Biol Sci, Nara 6300101, Japan
关键词
flow-cytometric cell sorting; gel microdroplets; microcolony; Saccharomyces cerevisiae; screening of microorganisms; thiamin production;
D O I
10.1016/S0167-7012(00)00179-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescent labels used to disclose cellular function and the like are generally needed for cytometric analysis, but suitable ones are not always available, Thiamin, an example of such a label, was used as a model in this study. Thiamin in cells of bakers' yeast can be chemically converted to thiochrome, which fluoresces strongly, but the reaction kills cells not protected inside a gel microdroplet (GMD). Our new procedure for preparation of a small amount of GMDs uses a glass filter with micropores uniform in size to make an emulsion of molten agar in mineral oil that is then chilled for gelation of the agarose. Cells were suspended and mixed with the war-m agarose, which was used to make GMDs. Cells were grown into microcolonies in the GMDs, which were then treated to convert thiamin to thiochrome. The thiochrome in microcolonies in single GMDs could be detected by flow cytometry. Plating showed that enough cells survived for this method to be used for screening. This technique can be used for all applications of GMDs. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 6 条
[1]  
[Anonymous], 1992, KEY ENG MAT, DOI [DOI 10.4028/WWW.SCIENTIFIC.NET/KEM.61-62.513, 10.4028/www.scientific.net/KEM.61-62.513]
[2]   DIFFERENTIAL FLUORIMETRIC DETERMINATION OF PICOGRAM LEVELS OF THIAMINE, THIAMINE MONOPHOSPHATE, DIPHOSPHATE AND TRIPHOSPHATE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KIMURA, M ;
FUJITA, T ;
NISHIDA, S ;
ITOKAWA, Y .
JOURNAL OF CHROMATOGRAPHY, 1980, 188 (02) :417-419
[3]   SINGLE-CELL ENTRAPMENT AND MICROCOLONY DEVELOPMENT WITHIN UNIFORM MICROSPHERES AMENABLE TO FLOW-CYTOMETRY [J].
NIR, R ;
LAMED, R ;
GUETA, L ;
SAHAR, E .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1990, 56 (09) :2870-2875
[4]   MICROBIOLOGICAL MEASUREMENTS BY IMMOBILIZATION OF CELLS WITHIN SMALL-VOLUME ELEMENTS [J].
WEAVER, JC ;
SEISSLER, PE ;
THREEFOOT, SA ;
LORENZ, JW ;
HUIE, T ;
RODRIGUEZ, R ;
KLIBANOV, AM .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES-SERIES, 1984, 434 (DEC) :363-372
[5]  
WEAVER JC, 1986, BIOTECHNOL BIOENG S, V17, P185
[6]  
Wyatt DT, 1997, METHOD ENZYMOL, V279, P91