Analytical versus voxelized phantom representation for Monte Carlo simulation in radiological imaging

被引:34
作者
Peter, J [1 ]
Tornai, MP [1 ]
Jaszczak, RJ [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
关键词
analytical phantoms; discretization; Monte Carlo methods; PET; SPECT; voxelized phantoms;
D O I
10.1109/42.870266
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Monte Carlo simulations in nuclear medicine, with accurately modeled photon transport and high-quality random number generators, require precisely defined and often detailed phantoms as an important component in the simulation process. Contemporary simulation models predominantly employ voxel-driven algorithms, but analytical models offer important advantages. We discuss the implementation of ray-solid intersection algorithms in analytical superquadric-based complex phantoms with additional speed-up rejection testing for use in nuclear medicine imaging simulations, and we make comparisons with voxelized counterparts. Comparisons are made with well-known cold rod:sphere and anthropomorphic phantoms, For these complex phantoms, the analytical phantom representations are nominally several orders of magnitude smaller in memory requirements than are voxelized versions. Analytical phantoms facilitate constant distribution parameters. As a consequence of discretizing a continuous surface into finite bins, for example, time-dependent voxelized phantoms can have difficulties preserving accurate volumes of a beating heart. Although virtually no inaccuracy is associated with path calculations in analytical phantoms, the discretization can negatively impact the simulation process and results. Discretization errors are apparent in reconstructed images of cold rod:sphere voxel-based phantoms because of a redistribution of the count densities in the simulated objects. These problems are entirely avoided in analytical phantoms. Voxelized phantoms can accurately model detailed human shapes based on segmented computed tomography (CT) or magnetic resonance imaging (MRI) images, but analytical phantoms offer advantages in time and accuracy for evaluation and investigation of imaging physics and reconstruction algorithms in a straightforward and efficient manner.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 37 条
[1]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[2]  
BAI C, 1999, P 1999 INT M FULL 3, P293
[3]  
Barr A. H., 1981, IEEE Computer Graphics and Applications, V1, P11, DOI 10.1109/MCG.1981.1673799
[4]   Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation [J].
Beekman, FJ ;
de Jong, HWAM ;
Slijpen, ETP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08) :N183-N192
[5]  
CYCHOSZ J, 1991, GRAPHICS GEMS, V2, P251
[6]  
Cychosz J. M., 1992, GRAPHICS GEMS, P275
[7]   MONTE-CARLO EVALUATION OF COMPTON SCATTER SUBTRACTION IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY [J].
FLOYD, CE ;
JASZCZAK, RJ ;
HARRIS, CC ;
GREER, KL ;
COLEMAN, RE .
MEDICAL PHYSICS, 1985, 12 (06) :776-778
[8]   MODELING THE SCATTER RESPONSE FUNCTION IN INHOMOGENEOUS SCATTERING MEDIA FOR SPECT [J].
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1585-1593
[9]  
HAM G, 1999, P IEEE NUCL SCI S ME, pM10
[10]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620