摘要
A rapid determination of benzene, toluene, ethylbenzene and the three xylene isomers (BTEX), including a nearly baseline separation of the xylene isomers in environmental samples within 1 min has been carried out using low-pressure gas chromatography-ion trap mass spectrometry (LP-GC-IT-MS). In order to evaluate the different parameters which may influence the performance of LP-GC-IT-MS, different column and mass spectral parameters were varied. Comparing LP-GC-IT-MS with the conventional equivalent, we obtained excellent detection limits as well as a good RSD of 8-13% in addition to a much shorter analysis time. In order to evaluate LP-GC-IT-MS for use in environmental samples, we determined BTEX in air. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 13 条
[1]   CONSIDERATION ON SPEED OF SEPARATION, DETECTION, AND IDENTIFICATION LIMITS IN CAPILLARY GC AND GC/MS [J].
CRAMERS, CA ;
LECLERCQ, PA .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (02) :117-147
[2]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS CHROMATOGRAPHY-MASS SPECTROMETRY SYSTEMS - CAPILLARY COLUMNS AT SUB-ATMOSPHERIC OUTLET PRESSURES [J].
CRAMERS, CA ;
SCHERPENZEEL, GJ ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :207-216
[3]   High-speed gas chromatography: an overview of various concepts [J].
Cramers, CA ;
Janssen, HG ;
van Deursen, MM ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :315-329
[4]  
Dagan S, 1996, J AM SOC MASS SPECTR, V7, P737, DOI 10.1016/1044-0305(96)80519-8
[5]  
DEZEEUW J, 1999, P 21 INT S CAP CHROM
[6]  
LECLERCQ PA, 1985, J HIGH RES CHROMATOG, V8, P764, DOI 10.1002/jhrc.1240081112
[7]  
Leclercq PA, 1998, MASS SPECTROM REV, V17, P37, DOI 10.1002/(SICI)1098-2787(1998)17:1<37::AID-MAS2>3.0.CO
[8]  
2-A
[9]  
LECLERCQ PA, 1992, J HIGH RES CHROMATOG, V15, P532
[10]   DIRECT COUPLING OF HIGH-RESOLUTION OPEN-HOLE GLASS TUBULAR COLUMNS TO A MASS-SPECTROMETER FOR BIOCHEMICAL APPLICATIONS [J].
LEFERINK, JG ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1974, 91 (APR24) :385-391