The assessment of intraobserver and interobserver error in the measurement of noncongenital scoliosis in children ≤ 10 years of age

被引:74
作者
Loder, RT
Spiegel, D
Gutknecht, S
Kleist, K
Ly, T
Mehbod, A
机构
[1] James Whitcomb Riley Hosp Children, Indianapolis, IN 46202 USA
[2] Shriners Hosp Children, Minneapolis, MN USA
[3] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55455 USA
[4] Twim Cities Spine Ctr, Minneapolis, MN USA
关键词
scoliosis; measurement variability; interobserver; intraobserver; noncongenital; children;
D O I
10.1097/01.brs.0000144828.72721.d8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Retrospective review of scoliosis radiographs. Objectives. To determine measurement variability in children less than or equal to 10 years of age with noncongenital scoliosis. Summary of Background Data. Measurement variability in congenital and adolescent idiopathic scoliosis has been studied. There is no study of measurement variability in young children with noncongenital scoliosis. Methods. A retrospective review of children less than or equal to 10 years of age followed for noncongenital scoliosis was performed. End vertebrae were identified on radiographs, and the curves were measured ( Cobb method) twice by each of six observers. The same soft lead pencil and goniometer was used. Intraobserver and interobserver variability for continuous data was determined. Results. There were 64 children. The diagnosis was infantile/juvenile idiopathic scoliosis in 42, neuromuscular scoliosis in 7, scoliosis associated with mesenchymal disorders or other syndromes in 12, and unknown in 3 children. The curve was thoracic in 54, thoracolumbar in 8, and lumbar in 2. There were 19 left and 45 right curves. The average age was 6.6 +/- 2.6 years. There were a total of 768 Cobb angle measurements with an average Cobb angle of 38 +/- 22degrees (range, 10degrees - 115degrees). Intraobserver variability was +/-6degrees; interobserver variability was +/- 7degrees. Conclusion. In children less than or equal to 10 years of age with noncongenital scoliosis, intraobserver measurement variability in Cobb angle measurement is +/-6degrees and interobserver variability is +/-7degrees. To be certain that there is a significant difference between Cobb angle measurements in children with noncongenital scoliosis and less than or equal to10 years of age there must be a change of at least +/-7degrees.
引用
收藏
页码:2548 / 2553
页数:6
相关论文
共 15 条
[1]
DIURNAL-VARIATION OF COBB ANGLE MEASUREMENT IN ADOLESCENT IDIOPATHIC SCOLIOSIS [J].
BEAUCHAMP, M ;
LABELLE, H ;
GRIMARD, G ;
STANCIU, C ;
POITRAS, B ;
DANSEREAU, J .
SPINE, 1993, 18 (12) :1581-1583
[2]
COMPARING 2 METHODS OF CLINICAL MEASUREMENT - A PERSONAL HISTORY [J].
BLAND, JM ;
ALTMAN, DG .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1995, 24 :S7-S14
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION [J].
CARMAN, DL ;
BROWNE, RH ;
BIRCH, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :328-333
[5]
A CLINICAL-STUDY OF THE DIFFERENCES BETWEEN THE SCOLIOTIC ANGLES MEASURED ON POSTEROANTERIOR AND ANTEROPOSTERIOR RADIOGRAPHS [J].
DESMET, AA ;
GOIN, JE ;
ASHER, MA ;
SCHEUCH, HG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (04) :489-493
[6]
DUTTON K E, 1989, Australasian Physical and Engineering Sciences in Medicine, V12, P16
[7]
STATISTICAL METHODOLOGY FOR THE CONCURRENT ASSESSMENT OF INTERRATER AND INTRARATER RELIABILITY - USING GONIOMETRIC MEASUREMENTS AS AN EXAMPLE [J].
ELIASZIW, M ;
YOUNG, SL ;
WOODBURY, MG ;
FRYDAYFIELD, K .
PHYSICAL THERAPY, 1994, 74 (08) :777-788
[8]
Measurement accuracy in congenital scoliosis [J].
Facanha, FAM ;
Winter, RB ;
Lonstein, JE ;
Koop, S ;
Novacheck, T ;
L'Heureux, EA ;
Noren, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (01) :42-45
[9]
OBSERVER VARIATION IN ASSESSING SPINAL CURVATURE AND SKELETAL DEVELOPMENT IN ADOLESCENT IDIOPATHIC SCOLIOSIS [J].
GOLDBERG, MS ;
POITRAS, B ;
MAYO, NE ;
LABELLE, H ;
BOURASSA, R ;
CLOUTIER, R .
SPINE, 1988, 13 (12) :1371-1377
[10]
COMPUTERIZED MEASUREMENT AND ANALYSIS OF SCOLIOSIS - MORE ACCURATE REPRESENTATION OF THE SHAPE OF THE CURVE [J].
JEFFRIES, BF ;
TARLTON, M ;
DESMET, AA ;
DWYER, SJ ;
BROWER, AC .
RADIOLOGY, 1980, 134 (02) :381-385