Effect of pollution from Central American fires on cloud-to-ground lightning in May 1998

被引:69
作者
Murray, ND [1 ]
Orville, RE [1 ]
Huffines, GR [1 ]
机构
[1] Texas A&M Univ, Dept Atmospher Sci, Cooperat Inst Appl Meteorol Studies, College Stn, TX 77843 USA
关键词
D O I
10.1029/2000GL011656
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
In the spring of 1998, numerous fires from seasonal biomass burning in Central America, mainly in Mexico and Guatemala, produced aerosol particles that were advected into the central plains of the United States. The effects of the fires continued from approximately April 9 through June 11. The most intense smoke concentration was on May 8 as seen from a NASA Shuttle mission. Characteristics of cloud-to-ground (CG) lightning flashes recorded by the National Lightning Detection Network were examined for May 1998 by subtracting the lightning characteristics for May 1995-1997, and 1999 This produces "difference value" maps with approximately 100 km resolution for polarity, peak currents, and multiplicity. Several significant differences are revealed. The percentage of positive flashes increased by a factor of two. Median first stroke peak currents have been calculated for both positive and negative flashes. For negative flashes, the median peak current decreased during the fire period. For positive flashes, the median peak current increased by over 20 kA in Texas, Oklahoma, Kansas, Arkansas and Nebraska. Mean multiplicity values, or the number of strokes per flash, were calculated. Positive flash multiplicity did not change. Mean multiplicity values for negative flashes, however, changed dramatically. For a region including Texas, Oklahoma, Kansas, and Louisiana multiplicity values for negative flashes decreased from 2.8 to 1.0-1.4 strokes per flash. The data analyzed were a corrected set from which we had deleted positive flashes with peak currents less than 10 kA, thus removing most of the intracloud contamination. Further studies may reveal the relation between the effect of pollution and aerosol size on the characteristics of CG flashes.
引用
收藏
页码:2249 / 2252
页数:4
相关论文
共 15 条
[1]   A combined TOA/MDF Technology Upgrade of the US National Lightning Detection Network [J].
Cummins, KL ;
Murphy, MJ ;
Bardo, EA ;
Hiscox, WL ;
Pyle, RB ;
Pifer, AE .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1998, 103 (D8) :9035-9044
[2]   Performance evaluation of the US National Lightning Detection Network in eastern New York - 1. Detection efficiency [J].
Idone, VP ;
Davis, DA ;
Moore, PK ;
Wang, Y ;
Henderson, RW ;
Ries, M ;
Jamason, PF .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1998, 103 (D8) :9045-9055
[3]   Performance evaluation of the US National Lightning Detection Network in eastern New York - 2. Location accuracy [J].
Idone, VP ;
Davis, DA ;
Moore, PK ;
Wang, Y ;
Henderson, RW ;
Ries, M ;
Jamason, PF .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1998, 103 (D8) :9057-9069
[4]  
KAYIN S, 1999, PM 10 CONCENTRATIONS
[5]   Enhanced positive cloud-to-ground lightning in thunderstorms ingesting smoke from fires [J].
Lyons, WA ;
Nelson, TE ;
Williams, ER ;
Cramer, JA ;
Turner, TR .
SCIENCE, 1998, 282 (5386) :77-80
[6]  
MURRAY ND, 85721 AZ U AR
[7]  
Orville RE, 1999, MON WEATHER REV, V127, P2693, DOI 10.1175/1520-0493(1999)127<2693:LGFMOT>2.0.CO
[8]  
2
[9]  
ORVILLE RE, 778433150 TEX A M U
[10]  
ORVILLE RE, 1997, MON WEA REV, V122, P1740