Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland

被引:27
作者
Aroua, A
Besançon, A
Buchillier-Decka, I
Trueb, P
Valley, JF
Verdun, FR
Zeller, W
机构
[1] Univ Lausanne, Inst Appl Radiat Phys, CH-1007 Lausanne, Switzerland
[2] Swiss Fed Off Publ Hlth, CH-3003 Bern, Switzerland
关键词
D O I
10.1093/rpd/nch343
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
This work aims at establishing a set of diagnostic reference levels (DRLs) for various types of examinations performed in diagnostic and interventional radiology. The average doses for 257 types of radiological examinations were established during the 1998 nationwide survey on the exposure of the Swiss population by radiodiagnostics. They were calculated using appropriate dosimetric models and average technical parameters. The DRLs were derived from the average doses using a multiplying factor of 1.5. The DRLs obtained were rounded and compared to the data reported in the literature. The results are in most cases comparable to the DRLs determined by the 3rd-quartile method. These discrepancies registered in some cases, particularly for complex examinations, can be explained by significant differences in the protocols and/or the technical parameters used. A set of DRLs is proposed for a large number of examinations to be used in Switzerland as temporary values until a national dosimetric database is set up.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 42 条
[1]
Nation-wide survey on radiation doses in diagnostic and interventional radiology in Switzerland in 1998 [J].
Aroua, A ;
Burnand, B ;
Decka, I ;
Vader, JP ;
Valley, JF .
HEALTH PHYSICS, 2002, 83 (01) :46-55
[2]
Dosimetric aspects of a national survey of diagnostic and interventional radiology in Switzerland [J].
Aroua, A ;
Decka, I ;
Burnand, B ;
Vader, JP ;
Valley, JF .
MEDICAL PHYSICS, 2002, 29 (10) :2247-2259
[3]
AROUA A, 2002, NIVEAUX REFERENCE DI
[4]
Reference doses during fluoroscopic procedures [J].
Broadhead, DA ;
Chapple, CL ;
Faulkner, K .
RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) :143-144
[5]
Local reference doses during cardiology procedures [J].
Broadhead, DA ;
Chapple, CL ;
Faulkner, K ;
Davies, ML ;
McCallum, H .
RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) :149-150
[6]
The relevance of different quantities for risk estimation in diagnostic radiology [J].
Broerse, JJ ;
Geleijns, J .
RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) :33-37
[7]
CONNOLLY PA, 2000, RTD003420 ERPET
[8]
CORBETT RH, 2000, P 10 INT C INT RAD P
[9]
COURSEY BM, 1999, APPL RADIAT ISOTOPES, V50, P1
[10]
Estimation of effective dose in some digital angiographic and interventional procedures [J].
Cruces, RR ;
García-Granados, J ;
Romero, FJD ;
Armas, JH .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :42-47