Highly resolved chemical imaging of living cells by using synchrotron infrared microspectrometry

被引:228
作者
Jamin, N
Dumas, P
Moncuit, J
Fridman, WH
Teillaud, JL
Carr, GL
Williams, GP
机构
[1] Ctr Univ Paris Sud, Utilisat Rayonnement Electromagnet Lab, F-91405 Orsay, France
[2] CEA, Inst Natl Sci & Tech Nucl, F-91191 Gif Sur Yvette, France
[3] Ctr Univ Paris Sud, CNRS, Lab Spect Infrarouge & Raman, F-91405 Orsay, France
[4] Inst Curie, INSERM, U255, F-75248 Paris 05, France
[5] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11974 USA
关键词
D O I
10.1073/pnas.95.9.4837
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Using synchrotron radiation as an ultrabright infrared source, we have been able to map the distributions of functional groups such as proteins, lipids, and nucleic acids inside a single living cell with a spatial resolution of a few microns. In particular, we have mapped the changes in the lipid and protein distributions in both the final stages of cell division and also during necrosis.
引用
收藏
页码:4837 / 4840
页数:4
相关论文
共 14 条
[1]   REGULATORY EFFECTS OF IGG-BF ON HYBRIDOMA-B CELLS - MOLECULAR CHARACTERIZATION OF VARIANT CELL-LINES [J].
BRUNATI, S ;
MIOSSEC, C ;
MATHIOT, C ;
MONCUIT, J ;
AMIGORENA, S ;
TEILLAUD, JL ;
FRIDMAN, WH .
MOLECULAR IMMUNOLOGY, 1988, 25 (11) :1133-1142
[2]   MIDINFRARED BEAMLINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE PORT U2B [J].
CARR, GL ;
HANFLAND, M ;
WILLIAMS, GP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1643-1645
[3]   PERFORMANCE OF AN INFRARED MICROSPECTROMETER AT THE NSLS [J].
CARR, GL ;
REFFNER, JA ;
WILLIAMS, GP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1490-1492
[4]  
CONRAD GW, 1990, ANN NY ACAD SCI, V582, P273
[5]   INFRARED SYNCHROTRON RADIATION FROM ELECTRON STORAGE-RINGS [J].
DUNCAN, WD ;
WILLIAMS, GP .
APPLIED OPTICS, 1983, 22 (18) :2914-2923
[6]  
Griffiths P.R., 1986, FOURIER TRANSFORM IN
[7]  
PETICOLAS WL, 1995, METHOD ENZYMOL, V246, P389
[8]   LASER IRRADIATION AND RAMAN-SPECTROSCOPY OF SINGLE LIVING CELLS AND CHROMOSOMES - SAMPLE DEGRADATION OCCURS WITH 514.5NM BUT NOT WITH 660NM LASER-LIGHT [J].
PUPPELS, GJ ;
OLMINKHOF, JHF ;
SEGERSNOLTEN, GMJ ;
OTTO, C ;
DEMUL, FFM ;
GREVE, J .
EXPERIMENTAL CELL RESEARCH, 1991, 195 (02) :361-367
[9]   STUDYING SINGLE LIVING CELLS AND CHROMOSOMES BY CONFOCAL RAMAN MICROSPECTROSCOPY [J].
PUPPELS, GJ ;
DEMUL, FFM ;
OTTO, C ;
GREVE, J ;
ROBERTNICOUD, M ;
ARNDTJOVIN, DJ ;
JOVIN, TM .
NATURE, 1990, 347 (6290) :301-303
[10]  
SIEBERT F, 1995, METHOD ENZYMOL, V246, P501