A novel validated procedure for the determination of nicotine, eight nicotine metabolites and two minor tobacco alkaloids in human plasma or urine by solid-phase extraction coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry

被引:112
作者
Miller, Eleanor I. [1 ]
Norris, Hye-Ryun K. [1 ]
Rollins, Douglas E. [1 ]
Tiffany, Stephen T. [2 ]
Wilkins, Diana G. [1 ]
机构
[1] Univ Utah, Ctr Human Toxicol, Dept Pharmacol & Toxicol, Salt Lake City, UT 84108 USA
[2] SUNY Buffalo, Dept Psychol, Buffalo, NY 14260 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 9-10期
关键词
Nicotine and nicotine metabolites; Plasma/urine; LC-ESI-MS/MS; 7-mg transdermal nicotine patch; 5 MAJOR METABOLITES; COTININE; ANABASINE; SMOKERS; SALIVA; SERUM;
D O I
10.1016/j.jchromb.2009.12.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) procedure was developed and fully validated for the simultaneous determination of nicotine-N-beta-D-glucuronide, cotinine-N-oxide, trans-3-hydroxycotinine, norcotinine, trans-nicotine-1'-oxide, cotinine, nornicotine, nicotine, anatabine, anabasine and cotinine-N-beta-D-glucuronide in human plasma or urine. Target analytes and corresponding deuterated internal standards were extracted by solid-phase extraction and analyzed by LC-MS/MS with electrospray ionization (ESI) using multiple reaction monitoring (MRM) data acquisition. Calibration curves were linear over the selected concentration ranges for each analyte, with calculated coefficients of determination (R-2) of greater than 0.99. The total extraction recovery (%) was concentration dependent and ranged between 52-88% in plasma and 51-118% in urine. The limits of quantification for all analytes in plasma and urine were 1.0 ng/mL and 2.5 ng/mL, respectively, with the exception of cotinine-N-beta-D-glucuronide, which was 50 ng/mL. Intra-day and inter-day imprecision were <= 14% and <= 17%, respectively. Matrix effect (%) was sufficiently minimized to <= 19% for both matrices using the described sample preparation and extraction methods. The target analytes were stable in both matrices for at least 3 freeze-thaw cycles, 24 h at room temperature, 24 h in the refrigerator (4 degrees C) and 1 week in the freezer (-20 degrees C). Reconstituted plasma and urine extracts were stable for at least 72 h storage in the liquid chromatography autosampler at 4 degrees C. The plasma procedure has been successfully applied in the quantitative determination of selected analytes in samples collected from nicotine-abstinent human participants as part of a pharmacokinetic study investigating biomarkers of nicotine use in plasma following controlled low dose (7 mg) transdermal nicotine delivery. Nicotine, cotinine, trans-3-hydroxycotinine and trans-nicotine-1'-oxide were detected in the particular sample presented herein. The urine procedure has been used to facilitate the monitoring of unauthorized tobacco use by clinical study participants at the time of physical examination (before enrollment) and on the pharmacokinetic study day. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:725 / 737
页数:13
相关论文
共 31 条
[1]  
Adhikari B., 2008, Morbidity and Mortality Weekly Report, V57, P1226
[2]  
[Anonymous], 1992, RESP HLTH EFFECTS PA
[3]  
[Anonymous], 2009, NSDUH SER
[4]  
Armstrong DW, 1999, CHIRALITY, V11, P82, DOI 10.1002/(SICI)1520-636X(1999)11:1<82::AID-CHIR14>3.0.CO
[5]  
2-C
[6]   METABOLISM OF NICOTINE TO COTININE STUDIED BY A DUAL STABLE-ISOTOPE METHOD [J].
BENOWITZ, NL ;
JACOB, P .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1994, 56 (05) :483-493
[7]   Trans-3′-hydroxycotinine:: Disposition kinetics, effects and plasma levels during cigarette smoking [J].
Benowitz, NL ;
Jacob, P .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2001, 51 (01) :53-59
[8]   Cotinine as a biomarker of environmental tobacco smoke exposure [J].
Benowitz, NL .
EPIDEMIOLOGIC REVIEWS, 1996, 18 (02) :188-204
[9]  
CLARKE PBS, 1995, EFFECTS NICOTINE BIO, V2
[10]   Determination of nicotine and its major metabolite cotinine in plasma or serum by gas chromatography-mass spectrometry using ion-trap detection [J].
Cognard, E ;
Staub, C .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (12) :1599-1607