Development of a compact supersonic jet/multiphoton ionization/time-of-flight mass spectrometer for the on-site analysis of dioxin, part I: Evaluation of basic performance

被引:22
作者
Matsumoto, J
Nakano, B
Imasaka, T [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Higashi Ku, Fukuoka 8128581, Japan
[2] Ulvac Kyushu Corp, Fukuoka 8191613, Japan
关键词
D O I
10.2116/analsci.19.379
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of compact supersonic jet/resonance-enhanced multiphoton ionization/time-of-flight mass spectrometer is described. The analytical instrument, consisting of a single turbo molecular pump equipped with a rotary pump, was maintained at < 2 x 10(-3) Pa when a 0.3-atm sample was injected into a vacuum at 10-Hz using a 200-mus pulse valve. The diameters of the extraction and ground skimmer electrodes were expanded to 30 mm in order to avoid strong focusing and defocusing of the ion, and the optimum conditions for the system were investigated. The mass spectrometer functioned as expected: (1) no defocusing of the ion beam was observed even when the potential of the einzel lens was adjusted to zero; (2) the direction of the ion beam to an assembly of microchannel plates deviated in the expected manner when the potential of the defection electrode was changed from 0 to 30 V.
引用
收藏
页码:379 / 382
页数:4
相关论文
共 15 条
[1]   Identification of surrogate compounds for the emission of PCDD/F (I-TEQ value) and evaluation of their on-line realtime detectability in flue gases of waste incineration plants by REMPI-TOFMS mass spectrometry [J].
Blumenstock, M ;
Zimmermann, R ;
Schramm, KW ;
Kettrup, A .
CHEMOSPHERE, 2001, 42 (5-7) :507-518
[2]   A capillary-based supersonic jet inlet system for resonance-enhanced laser ionization mass spectrometry: Principle and first on-line process analytical applications [J].
Hafner, K ;
Zimmermann, R ;
Rohwer, ER ;
Dorfner, R ;
Kettrup, A .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4171-4180
[3]   SUPERSONIC JETS, ROTATIONAL COOLING, AND ANALYTICAL-CHEMISTRY [J].
HAYES, JM ;
SMALL, GJ .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :A565-&
[4]   ANALYTICAL SPECTROSCOPY IN SUPERSONIC EXPANSIONS [J].
HAYES, JM .
CHEMICAL REVIEWS, 1987, 87 (04) :745-760
[5]   HIGH-TEMPERATURE PULSED NOZZLE FOR SUPERSONIC JET SPECTROMETRY AND ITS APPLICATION TO GAS-CHROMATOGRAPHY [J].
IMASAKA, T ;
OKAMURA, T ;
ISHIBASHI, N .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2152-2155
[6]   OPTICALLY SELECTIVE MOLECULAR MASS-SPECTROMETRY [J].
LUBMAN, DM .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :A31-A40
[7]   Effect of laser pulse width on ionization efficiency in supersonic beam-multiphoton ionization mass spectrometry [J].
Matsumoto, J ;
Imasaka, T .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3763-3768
[8]   Use of ring-repeller, double-skimmer electrodes for efficient ion focusing in mass spectrometry [J].
Matsumoto, J ;
Saito, G ;
Imasaka, T .
ANALYTICAL SCIENCES, 2002, 18 (05) :567-570
[9]   A mobile mass spectrometer for comprehensive on-line analysis of trace and bulk components of complex gas mixtures:: Parallel application of the laser-based ionization methods VUV single-photon ionization, resonant multiphoton ionization, and laser-induced electron impact ionization [J].
Mühlberger, F ;
Zimmermann, R ;
Kettrup, A .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3590-3604
[10]   Development of a jet-REMPI (resonantly enhanced multiphoton ionization) continuous monitor for environmental applications [J].
Oser, H ;
Coggiola, MJ ;
Faris, GW ;
Young, SE ;
Volquardsen, B ;
Crosley, DR .
APPLIED OPTICS, 2001, 40 (06) :859-865