Tests of global haemostasis and their applications in bleeding disorders

被引:66
作者
Nair, S. C.
Dargaud, Y. [2 ,3 ]
Chitlur, M. [4 ]
Srivastava, A. [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Haematol, Vellore 632004, Tamil Nadu, India
[2] Hop Edouard Herriot, Unite Hemostase Clin, Lyon, France
[3] Univ Lyon 1, Unite Rech Hemophilie, EA 4174, F-69622 Villeurbanne, France
[4] Wayne State Univ, Childrens Hosp Michigan, Detroit, MI USA
关键词
global; haemophilia; haemostasis; heterogeneity; phenotype; thrombin; PARTIAL THROMBOPLASTIN TIME; HEMOPHILIA-A PATIENTS; WAVE-FORM ANALYSIS; THROMBIN GENERATION; FACTOR-VIII; COAGULATION DISORDERS; BLOOD-COAGULATION; PROTHROMBIN TIME; FACTOR-IX; INHIBITOR;
D O I
10.1111/j.1365-2516.2010.02304.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is a potential for significant paradigm shift in the assessment of haemostasis from the conventional plasma recalcification times, such as prothrombin time (PT) and activated partial thromboplastin time (APTT), which correspond to artificially created compartments of haemostasis to tests that assess the entire process in a more physiological and holistic manner. These include the thrombin generation test, thromboelastogram and the clot wave form analysis. While these tests have been described many years ago, there is renewed interest in their use with modified technology for assessing normal haemostasis and its disorders. Although early data suggest that they can provide much greater information regarding the overall haemostasis process and its disorders, many challenges remain. Some of them are possible only on instruments that are proprietary technology, expensive and are not widely available. Furthermore, these tests need to be standardized with regard to their reagents, methodology and interpretation, and finally, much more data need to be collected regarding clinical correlations with the parameters measured.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 37 条
[1]   The thrombogram in rare inherited coagulation disorders:: Its relation to clinical bleeding [J].
Al Dieri, R ;
Peyvandi, F ;
Santagostino, E ;
Giansily, M ;
Mannucci, PM ;
Schved, JF ;
Béguin, S ;
Hemker, HC .
THROMBOSIS AND HAEMOSTASIS, 2002, 88 (04) :576-582
[2]   High rate of unprovoked recurrent venous thrombosis is associated with high thrombin-generating potential in a prospective cohort study [J].
Besser, M. ;
Baglin, C. ;
Luddington, R. ;
Vlieg, A. van Hylckama ;
Baglin, T. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2008, 6 (10) :1720-1725
[3]  
Braun PJ, 1997, THROMB HAEMOSTASIS, V78, P1079
[4]   Thromboelastography in children with coagulation factor deficiencies [J].
Chitlur, Meera ;
Warrier, Indira ;
Rajpurkar, Madhvi ;
Hollon, Wendy ;
Llanto, Lolita ;
Wiseman, Carol ;
Lusher, Jeanne M. .
BRITISH JOURNAL OF HAEMATOLOGY, 2008, 142 (02) :250-256
[5]   Assessment of platelet inhibition secondary to clopidogrel and aspirin therapy in preoperative acute surgical patients measured by Thrombelastography® Platelet Mapping™ [J].
Collyer, T. C. ;
Gray, D. J. ;
Sandhu, R. ;
Berridge, J. ;
Lyons, G. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (04) :492-498
[6]   Major surgery in a severe haemophilia A patient with high titre inhibitor: use of the thrombin generation test in the therapeutic decision [J].
Dargaud, Y ;
Lienhart, A ;
Meunier, S ;
Hequet, O ;
Chavanne, H ;
Chamouard, V ;
Marin, S ;
Negrier, C .
HAEMOPHILIA, 2005, 11 (05) :552-558
[7]   Evaluation of thrombin generating capacity in plasma from patients with haemophilia A and B [J].
Dargaud, Y ;
Béguin, S ;
Lienhart, A ;
Al Dieri, R ;
Trzeciak, C ;
Bordet, JC ;
Hemker, HC ;
Negrier, C .
THROMBOSIS AND HAEMOSTASIS, 2005, 93 (03) :475-480
[8]   Standardisation of thrombin generation test - which reference plasma for TGT?: An international multicentre study [J].
Dargaud, Y. ;
Luddington, R. ;
Gray, E. ;
Lecompte, T. ;
Siegemund, T. ;
Baglin, T. ;
Hogwood, J. ;
Regnault, V. ;
Siegemund, A. ;
Negrier, C. .
THROMBOSIS RESEARCH, 2010, 125 (04) :353-356
[9]   Thrombin generation testing in haemophilia comprehensive care centres [J].
Dargaud, Y. ;
Negrier, C. .
HAEMOPHILIA, 2010, 16 (02) :223-230
[10]   Effect of standardization and normalization on imprecision of calibrated automated thrombography: an international multicentre study [J].
Dargaud, Yesim ;
Luddington, Rodger ;
Gray, Elaine ;
Negrier, Claude ;
Lecompte, Thomas ;
Petros, Sirak ;
Hogwood, John ;
Bordet, Jean-Claude ;
Hogwood, John ;
Bordet, Jean-Claude ;
Regnault, Veronique ;
Siegemund, Annelie ;
Baglin, Trevor .
BRITISH JOURNAL OF HAEMATOLOGY, 2007, 139 (02) :303-309