Average 12-year outcome of a chrome-cobalt, beaded, bony ingrowth acetabular component

被引:23
作者
Smith, SE [1 ]
Estok, DM [1 ]
Harris, WH [1 ]
机构
[1] Massachusetts Gen Hosp, Orthopaed Biomech Lab, Boston, MA 02114 USA
关键词
Acetabular Reconstruction Component; Porous Coated Anatomic acetabular component; aseptic loosening; acetabular revision;
D O I
10.1016/S0883-5403(98)90075-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Seventy-two hips (67 patients) were reconstructed with the Acetabular Reconstruction Component (ARC, Howmedica, Rutherford, NJ), a chrome-cobalt component with sintered ingrowth beads and peripheral flanges for screw fixation. All the materials used in the ARC (metal, porous layer, and polyethylene) are identical to those used in the Porous Coated Anatomic (PCA) acetabular component (Howmedica), but the design is different. To determine the importance of design features alone, clinical results obtained with the 2 different designs made of identical materials were compared. The average follow-up period for patients with the ARC was 12 years (range, 10-13.3 years). Seven patients (7 hips) with the ARC died prior to the minimum 10-year follow-up period, none having undergone revision procedures. Overall, 3 acetabular components (4%) in 3 patients were revised, at an average of 8.5 years (range, 7.6-9.3 years) from the index operation. The reasons for revision were aseptic loosening third-body polyethylene wear observed during a revision for femoral lysis, and acetabular component malposition and recurrent dislocation. The total incidence of acetabular aseptic loosening was 4% (3 of 72 hips). Pelvic osteolysis occurred in 3 cases (4%). In contrast, the incidence of acetabular revision of the PCA acetabular component at follow-up periods of 2-10 years is reported to be as high as 11% (range, 3-11%). Rates of aseptic loosening are as high as 30% (range, 3-30%) at substantially shorter follow-up periods, and the incidence of pelvic osteolysis associated with the PCA component is also as high as 30% (range, 5-30%). These differences may reflect differences in design between the 2 acetabular components, as the materials used were identical. In this, the longest reported average follow-up study of a successful cementless acetabular component, the aseptic loosening rate of 4% contrasts with the 42% rate at similar follow-up duration for cemented acetabular components placed by the same surgeon in patients of similar age.
引用
收藏
页码:50 / 60
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]   IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[3]   PAIN ASSESSMENT IN OSTEO-ARTHRITIS - EXPERIENCE WITH THE WOMAC OSTEO-ARTHRITIS INDEX [J].
BELLAMY, N .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1989, 18 (04) :14-17
[4]   SIGNAL MEASUREMENT STRATEGIES - ARE THEY FEASIBLE AND DO THEY OFFER ANY ADVANTAGE IN OUTCOME MEASUREMENT IN OSTEOARTHRITIS [J].
BELLAMY, N ;
BUCHANAN, WW ;
GOLDSMITH, CH ;
CAMPBELL, J ;
DUKU, E .
ARTHRITIS AND RHEUMATISM, 1990, 33 (05) :739-745
[5]  
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[6]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[7]  
Charnley J., 1979, LOW FRICTION ARTHROP
[8]   TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP [J].
CROWE, JF ;
MANI, VJ ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) :15-23
[9]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20