Influence of speed and step frequency during walking and running on motion sensor output

被引:93
作者
Rowlands, Ann V. [1 ]
Stone, Michelle R. [1 ]
Eston, Roger G. [1 ]
机构
[1] Univ Exeter, Sch Sport & Hlth Sci, Exeter EX1 2LU, Devon, England
关键词
pedometer; accelerometer; uniaxial; triaxial; actigraph; RT3;
D O I
10.1249/mss.0b013e318031126c
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Studies have reported strong linear relationships between accelerometer output and walking/running speeds up to 10 km(.)h(-1). However, ActiGraph uniaxial accelerometer counts plateau at higher speeds. The aim of this study was to determine the relationships of triaxial accelerometry, uniaxial accelerometry, and pedometry with speed and step frequency (SF) across a range of walking and running speeds. Methods: Nine male runners wore two ActiGraph uniaxial accelerometers, two RT3 triaxial accelerometers (all set at a 1-s epoch), and two Yamax pedometers. Each participant walked for 60 s at 4 and 6 km(.)h(-1), ran for 60 s at 10, 12, 14, 16, and 18 km(.)h(-1), and ran for 30 s at 20, 22, 24, and 26 km-h-1. Step frequency was recorded by a visual count. Results: ActiGraph counts peaked at 10 km-h-1 (2.5-3.0 Hz SF) and declined thereafter (r = 0.02, P > 0.05). After correction for frequency-dependent filtering, output plateaued at 10 km-h-1 but did not decline (r = 0.77, P < 0.05). Similarly, RT3 vertical counts plateaued at speeds > 10 km(.)h(-1) (r = 0.86, P < 0.01). RT3 vector magnitude and anteroposterior and mediolateral counts maintained a linear relationship with speed (r > 0.96, P < 0.001). Step frequency assessed by pedometry compared well with actual step frequency up to 20 km(.)h(-1) (approximately 3.5 Hz) but then underestimated actual steps (Yamax r = 0.97; ActiGraph pedometer r = 0.88, both P < 0.001). Conclusion: Increasing underestimation of activity by the ActiGraph as speed increases is related to frequency-dependent filtering and assessment of acceleration in the vertical plane only. RT3 vector magnitude was strongly related to speed, reflecting the predominance of horizontal acceleration at higher speeds. These results indicate that high-intensity activity is underestimated by the ActiGraph, even after correction for frequency-dependent filtering, but not by the RT3. Pedometer output is highly correlated with step frequency.
引用
收藏
页码:716 / 727
页数:12
相关论文
共 26 条
[1]  
[Anonymous], 2003, Measurement in Physical Education and Exercise Science, DOI DOI 10.1207/S15327841MPEE0702_
[2]  
[Anonymous], META ANALYTIC PROCED
[3]   THE LEVEL AND TEMPO OF CHILDRENS PHYSICAL ACTIVITIES - AN OBSERVATIONAL STUDY [J].
BAILEY, RC ;
OLSON, J ;
PEPPER, SL ;
PORSZASZ, J ;
BARSTOW, TJ ;
COOPER, DM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1995, 27 (07) :1033-1041
[4]   Accuracy of five electronic pedometers for measuring distance walked [J].
Bassett, DR ;
Ainsworth, BE ;
Leggett, SR ;
Mathien, CA ;
Main, JA ;
Hunter, DC ;
Duncan, GE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) :1071-1077
[5]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[6]   Influence of step frequency on movement intensity predictions with the CSA accelerometer: A field validation study in children [J].
Brage, S ;
Wedderkopp, N ;
Andersen, LB ;
Froberg, K .
PEDIATRIC EXERCISE SCIENCE, 2003, 15 (03) :277-287
[7]  
Dillman C J, 1975, Exerc Sport Sci Rev, V3, P193
[8]  
DONNER A, 1984, MED SCI SPORT EXER, V16, P422
[9]   Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children's activities [J].
Eston, RG ;
Rowlands, AV ;
Ingledew, DK .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (01) :362-371
[10]   Calibration of the Computer Science and Applications, Inc. accelerometer [J].
Freedson, PS ;
Melanson, E ;
Sirard, J .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (05) :777-781