Single injection peribulbar anaesthesia - Total upper eyelid drop as an end-point marker

被引:21
作者
Frow, MW [1 ]
Miranda-Carabello, JI
Akhtar, TM
Hugkulstone, CE
机构
[1] Cent Middlesex Hosp, Dept Anaesthesia, London, England
[2] Kings Coll Hosp, London, England
[3] Queen Marys Hosp, Sidcup, Kent, England
关键词
anaesthesia; ophthalmic; anaesthetic techniques; peribulbar; anaesthetic; local; bupivacaine; lidocaine; surgery; ophthalmological;
D O I
10.1046/j.1365-2044.2000.01530.x
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
A prospective, observer blinded study on 51 patients undergoing cataract surgery was conducted to assess Total Upper Eyelid Drop as a new end-point marker to single injection peribulbar block. At present, Ilo such clinical marker exists to stop clinicians injecting more than necessary volumes of local anaesthetic and therefore to prevent dangerous increases in intra-ocular pressure. Using this technique, satisfactory ocular akinesia was achieved ill 90% of eyes 10 min after injection. Operating conditions were satisfactory in 98% of cases. The mean (range) volume injected was 9.1 (4-15) ml. The mean increase in intra-ocular pressure immediately after injection was 6.9 mmHg, decreasing to 0.7 mmHg after 5 min without the application of ocular compression. We found a negative correlation between the increase in intra-ocular pressure and the volume of injection (p < 0.002), which has never previously been reported. We conclude that Total Upper Eyelid Drop is a reliable endpoint marker for producing satisfactory operating conditions for cataract surgery while minimising increases in intra-ocular pressure and its use may therefore avoid the risks associated with ocular compression.
引用
收藏
页码:750 / 756
页数:7
相关论文
共 30 条
[1]
EVALUATION OF THE TONO-PEN AND THE PULSAIR TONOMETERS [J].
ARMSTRONG, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (06) :716-720
[2]
PLASMA-CATECHOLAMINE RESPONSE TO CATARACT-SURGERY - A COMPARISON BETWEEN GENERAL AND LOCAL-ANESTHESIA [J].
BARKER, JP ;
VAFIDIS, GC ;
ROBINSON, PN ;
HALL, GM .
ANAESTHESIA, 1991, 46 (08) :642-645
[3]
Postoperative morbidity following cataract surgery - A comparison of local and general anaesthesia [J].
Barker, JP ;
Vafidis, GC ;
Hall, GM .
ANAESTHESIA, 1996, 51 (05) :435-437
[4]
Peribulbar anaesthesia: a double-blind comparison of three local anaesthetic solutions [J].
Bedi, A ;
Carabine, U .
ANAESTHESIA, 1999, 54 (01) :67-71
[5]
BJORNSTROM L, 1994, ACTA OPHTHALMOL, V72, P712
[6]
Intraocular pressure changes after peribulbar injections with and without ocular compression [J].
Bowman, R ;
Liu, C ;
Sarkies, N .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (05) :394-397
[7]
A COMPARISON OF THE EFFECTS OF ALFENTANIL DROPERIDOL OR FENTANYL DROPERIDOL ON INTRAOCULAR-PRESSURE [J].
COLEY, S ;
JONES, GW ;
LASSEY, D ;
MAY, AE ;
FELL, D .
ANAESTHESIA, 1990, 45 (06) :477-480
[8]
ANESTHESIA FOR CATARACT-EXTRACTION [J].
DAVIS, DB ;
MANDEL, MR .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (02) :13-30
[9]
EFFICACY AND COMPLICATION RATE OF 16,224 CONSECUTIVE PERIBULBAR BLOCKS - A PROSPECTIVE MULTICENTER STUDY [J].
DAVIS, DB ;
MANDEL, MR .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (03) :327-337
[10]
Tonometry in adults and children -: A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo [J].
Eisenberg, DL ;
Sherman, BG ;
McKeown, CA ;
Schuman, JS .
OPHTHALMOLOGY, 1998, 105 (07) :1173-1181