On-line concentration and separation of proteins by capillary electrophoresis using polymer solutions

被引:76
作者
Tseng, WL [1 ]
Chang, HT [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 10764, Taiwan
关键词
D O I
10.1021/ac0004613
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Proteins were separated in 0.6% poly(ethylene oxide) (PEO) solutions using a capillary filled with buffers prior to analysis and were detected by laser-induced native fluorescence using a pulsed Nd:YAG laser. PEO solutions entered the capillary by electroosmotic how (EOF) during the separation. The composition and concentration of the buffer affected the adsorption of PEO molecules on the capillary surface and, consequently caused changes in the EOF. Short separation times (<7 min) were achieved on a sample solution of five proteins in a 0.6% PEO solution containing 5 mu g/mL ethidium bromide using a capillary pre-filled with 100 mM TRIS-borate (TB) buffers (pH 10,0). We also extended this method for on-line concentration and separation of proteins. Proteins dissolved in low-conductivity media stacked in both TB buffers and in PEO solutions. The peak height was proportional to the injection volume up to 2.1 mu L using an 80-cm capillary filled with 400 mM TB buffers. Using large injection volumes (2.1 mu L), are achieved a limit of detection (S/N = 3) of 31 pM for carbonic anhydrase, which was a 1696-fold sensitivity enhancement compared to a conventional injection method (1 kV for 10 s). In high-conductivity media (urine matrix), stacking occurred at the boundary between the sample zone and PEO solutions. A urine sample without any pretreatment was analyzed, and after stacking, several peaks were detected. Spiking the urine sample with human serum albumin (HSA) affected the fluorescent intensity of some analytes as a result of interaction with HSA.
引用
收藏
页码:4805 / 4811
页数:7
相关论文
共 58 条
[1]   Ultrasensitive detection of closely related angiotensin I peptides doing capillary electrophoresis with near-infrared laser-induced fluorescence detection [J].
Baars, MJ ;
Patonay, G .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :667-671
[2]   Fluorescent derivatization for low concentration protein analysis by capillary electrophoresis [J].
Banks, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (10) :612-622
[3]   Faster capillary electrophoresis separation of wheat proteins through modifications to buffer composition and sample handling [J].
Bean, SR ;
Lookhart, GL .
ELECTROPHORESIS, 1998, 19 (18) :3190-3198
[4]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS OF PROTEINS USING SODIUM DODECYL SULFATE-POLY(ETHYLENE OXIDE) [J].
BENEDEK, K ;
THIEDE, S .
JOURNAL OF CHROMATOGRAPHY A, 1994, 676 (01) :209-217
[5]   Analysis of recombinant human erythropoietin in drug formulations by high-performance capillary electrophoresis [J].
Bietlot, HP ;
Girard, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 759 (1-2) :177-184
[6]   STRUCTURE OF SOME POLYMER DETERGENT AGGREGATES IN WATER [J].
CABANE, B .
JOURNAL OF PHYSICAL CHEMISTRY, 1977, 81 (17) :1639-1645
[7]   Wheat cultivar discrimination by capillary electrophoresis of gliadins in isoelectric buffers [J].
Capelli, L ;
Forlani, F ;
Perini, F ;
Guerrieri, N ;
Cerletti, P ;
Righetti, PG .
ELECTROPHORESIS, 1998, 19 (02) :311-318
[8]   OPTIMIZATION OF SELECTIVITY IN CAPILLARY ZONE ELECTROPHORESIS VIA DYNAMIC PH GRADIENT AND DYNAMIC FLOW GRADIENT [J].
CHANG, HT ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :65-72
[9]  
CHANG HT, 1995, ANAL CHEM, V67, P2947
[10]   USE OF HIGH IONIC-STRENGTH BUFFERS FOR THE SEPARATION OF PROTEINS AND PEPTIDES WITH CAPILLARY ELECTROPHORESIS [J].
CHEN, FA ;
KELLY, L ;
PALMIERI, R ;
BIEHLER, R ;
SCHWARTZ, H .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1143-1161