Continuous on-line concentration based on dynamic pH junction for trimethoprim and sulfamethoxazole by microfluidic capillary electrophoresis combined with flow injection analysis system

被引:39
作者
Fan, LY [1 ]
Liu, LH [1 ]
Chen, HL [1 ]
Chen, XG [1 ]
Hu, ZD [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Gansu, Peoples R China
基金
中国国家自然科学基金;
关键词
microfluidic capillary electrophoresis; flow injection; dynamic pH junction; trimethoprim; sulfamethoxazole;
D O I
10.1016/j.chroma.2004.11.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, rapid and continuous on-line concentration approach based on dynamic pH junction for the analysis of trimethoprim, (TMP) and sulfamethoxazole (SMZ) by microfluidic capillary electrophoresis (CE) combined with flow injection analysis is developed in this paper. Stacking is due to decreases in the velocity of analytes when migrating from the low-pH sample zone (sample was dissolved in 50 MM HCl) to a relatively high-pH buffer (30 mM phosphate buffer, pH 8.5) filled in the capillary. This results in 2.9-4.7-fold improvement in concentration sensitivity relative to conventional capillary electrophoresis methods. The separation could be achieved within 2 min and sample throughput rate can reach up to 38 h(-1). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 39 条
[1]  
ALBIN M, 1993, ANAL CHEM, V65, P489
[2]  
[Anonymous], ANAL CHEM
[3]   On-line focusing of flavin derivatives using dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection [J].
Britz-McKibbin, P ;
Otsuka, K ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3736-3743
[4]   High-sensitivity analyses of metabolites introduction in biological samples by capillary electrophoresis using dynamic pH junction-sweeping [J].
Britz-McKibbin, P ;
Terabe, S .
CHEMICAL RECORD, 2002, 2 (06) :397-404
[5]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[6]   Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction [J].
Britz-McKibbin, P ;
Bebault, GM ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1729-1735
[7]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[8]   Improving separation efficiency of capillary zone electrophoresis of tryptophan and phenylalanine with the transient moving chemical reaction boundary method [J].
Cao, CX ;
He, YZ ;
Li, M ;
Qian, YT ;
Yang, L ;
Qu, QS ;
Zhou, SL ;
Chen, WK .
JOURNAL OF CHROMATOGRAPHY A, 2002, 952 (1-2) :39-46
[9]   Stacking ionizable analytes in a sample matrix with high salt by a transient moving chemical reaction boundary, method in capillary zone electrophoresis [J].
Cao, CX ;
He, YZ ;
Li, M ;
Qian, YT ;
Gao, MF ;
Ge, LH ;
Zhou, SL ;
Yang, L ;
Qu, QS .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4167-4174
[10]  
Chen HL, 2002, ELECTROPHORESIS, V23, P2865, DOI 10.1002/1522-2683(200209)23:17&lt