Passive dispersion of latex aeroallergen in a healthcare facility

被引:39
作者
Charous, BL
Schuenemann, PJ
Swanson, MC
机构
[1] Adv Healthcare SC, Div Allergy Immunol, Milwaukee Med Clin, Milwaukee, WI 53209 USA
[2] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
关键词
D O I
10.1016/S1081-1206(10)62531-8
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Prompted by worsening asthma in a dental assistant with latex allergy and occupational asthma while under personal latex precautions, we confirmed continuing latex aeroallergen exposure. Objectives: To determine the source of latex aeroallergen and ascertain the effects of site-wide substitution of nonpowdered low allergen latex glove in a health care site. Methods: Using a volumetric sampler, baseline latex aeroallergen levels were measured in rooms where she worked and nearby rooms, as well as shared X-ray, laboratory, and waiting rooms. Allergen levels were measured in upholstery fabric samples, ventilation duct dust, and latex gloves, Alterations in aeroallergen levels following change of glove types were prospectively determined. Results: Baseline latex aeroallergen levels ranged from 6 to 25 ng/m(3) in the patient's work areas and in other rooms from 29 to 90 ng/m(3) during work hours. Latex antigen was found in three brands of powdered latex gloves ((X) over bar = 1,156 mug/g) used in the nearby opertories and the hygiene room, and in upholstery fabric, carpet dust, but not ventilation duct dust. In the absence of any other control measures, airborne latex became undetectable (<5 ng/m(3)) with exclusive use of nonpowdered latex gloves. Discussion: Latex aeroallergen is primarily generated by active glove use; carpeting and fabric upholstery can serve as important aeroallergen repositories. Site-wide substitution of nonpowdered latex gloves eliminates detectable latex aeroallergen.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 22 条
[1]   Reduction of latex aeroallergens and latex-specific IgE antibodies in sensitized workers after removal of powdered natural rubber latex gloves in a hospital [J].
Allmers, H ;
Brehler, R ;
Chen, ZP ;
Raulf-Heimsoth, M ;
Fels, H ;
Baur, X .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1998, 102 (05) :841-846
[2]   Can a threshold limit value for natural rubber latex airborne allergens be defined? [J].
Baur, X ;
Chen, ZP ;
Allmers, H .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1998, 101 (01) :24-27
[3]  
BEEZHOLD D, 1992, ARCH SURG-CHICAGO, V127, P1354
[4]   OCCUPATIONAL LATEX EXPOSURE - CHARACTERISTICS OF CONTACT AND SYSTEMIC REACTIONS IN 47 WORKERS [J].
CHAROUS, BL ;
HAMILTON, RG ;
YUNGINGER, JW .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 94 (01) :12-18
[5]  
CHAROUS BL, 1995, ANN ALLERG ASTHMA IM, V75, P19
[6]  
CHAROUS BL, 1994, ANN ALLERGY, V73, P277
[7]   A prospective, controlled study showing that rubber gloves are the major contributor to latex aeroallergen levels in the operating room [J].
Heilman, DK ;
Jones, RT ;
Swanson, MC ;
Yunginger, JW .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (02) :325-330
[8]  
KARATHANASIS P, 1993, ANN ALLERGY, V71, P526
[9]  
PLATTSMILLS T, 1998, ALLERGY PRINCIPLES P, V1, P393
[10]  
REED CE, 1999, ASTHMA WORKPLACE, P235