Determination of trace lead impurities in pure copper slurry samples by electrothermal atomic absorption spectrometry with molybdenum tube atomizer

被引:7
作者
Ahsan, S [1 ]
Kaneco, S [1 ]
Ohta, K [1 ]
Mizuno, T [1 ]
机构
[1] Mie Univ, Fac Engn, Dept Chem Mat, Tsu, Mie 5148507, Japan
关键词
lead; slurry sampling; copper sample; electrothermal atomization; molybdenum tube atomizer;
D O I
10.1051/analusis:2000126
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for direct atomization of slurry sample by electrothermal atomic absorption spectrometry (SS-ETAAS) has been developed for the determination of trace lead impurities in commercially available pure copper using laboratory-made molybdenum tube atomizer. Suitable charring temperature was set and matrix element interference was checked. Lead standard solution in the glycerol-water medium as calibration medium and ultrasonic agitation method of the suspension of the sample powder were used. Typical results of this direct slurry method and wet digestion were close and precision varies over the range RSD 3.9 to 9.0 %. The recovery of Pb added was 98-102 %. Accuracy for certified copper sample agreed within 3 % range. Limits of detection were 34 fg Pb (3S/N), and characteristic mass 170 fg Pb. The method offers rapid calibration, simplified and fast analysis of lead in pure copper at lower cost.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 40 条
[1]   Direct determination of cadmium in calcium drug samples using electrothermal atomic absorption spectrometry with a metal tube atomizer and thiourea as a matrix modifier [J].
Ahsan, S ;
Kaneco, S ;
Ohta, K ;
Mizuno, T ;
Taniguchi, Y .
TALANTA, 1999, 48 (01) :63-69
[2]   Electrothermal atomic absorption spectrometric determination of lead in calcium drug samples by direct atomization technique [J].
Ahsan, S ;
Kaneco, S ;
Ohta, K ;
Mizuno, T ;
Suzuki, T ;
Miyada, M ;
Taniguchi, Y .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :279-284
[3]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[4]   DETERMINATION OF LEAD IN ILLICIT DRUGS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING PALLADIUM AS CHEMICAL MODIFIER [J].
BERMEJOBARRERA, P ;
MOREDAPINEIRO, A ;
MOREDAPINEIRO, J ;
BERMEJOBARRERA, A .
ANALYTICA CHIMICA ACTA, 1995, 310 (02) :355-367
[5]   Determination of trace metals (As, Cd, Hg, Pb and Sn) in marine sediment slurry samples by electrothermal atomic absorption spectrometry using palladium as a chemical modifier [J].
BermejoBarrera, P ;
BarcielaAlonso, MC ;
MoredaPineiro, J ;
GonzalezSixto, C ;
BermejoBarrera, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1235-1244
[6]  
BETTINELLI M, 1985, ANALYST, V19, P110
[7]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[8]   DETERMINATION OF TRACE-ELEMENTS IN HIGH-PURITY MOLYBDENUM TRIOXIDE BY SLURRY SAMPLING ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
DOCEKAL, B ;
KRIVAN, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :637-641
[9]   INVESTIGATIONS OF REACTIONS INVOLVED IN FLAMELESS ATOMIC-ABSORPTION PROCEDURES .1. APPLICATION OF HIGH-TEMPERATURE EQUILIBRIUM CALCULATIONS TO A MULTICOMPONENT SYSTEM WITH SPECIAL REFERENCE TO INTERFERENCE FROM CHLORINE IN FLAMELESS ATOMIC-ABSORPTION METHOD FOR LEAD IN STEEL [J].
FRECH, W ;
CEDERGREN, A .
ANALYTICA CHIMICA ACTA, 1976, 82 (01) :83-92
[10]  
HALLAM DC, 1977, WIRE J, V10, P115