Power mode ultrasound in preocclusive stenosis of the internal carotid artery.

被引:7
作者
Jung, EM [1 ]
Butter, F [1 ]
Rupp, N [1 ]
机构
[1] Rontgeninst Klinikum Passau, D-94032 Passau, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 07期
关键词
internal carotid artery; preocclusive stenosis; occlusion; power mode vascular ultrasound;
D O I
10.1055/s-2000-4646
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the accuracy of power mode (PM) vascular ultrasound in preocclusive (> 90%) stenosis of the extracranial internal carotid artery (ICA) compared to other diagnostic methods and to operative findings. Material and Methods: 50 patients with preocclusive stenosis have been examined in a prospective study by power mode and color flow duplex ultrasound, by triplane aortic arch and four plane selective DSA. In 11 cases a MR angiography (time-of-flight) was available. Diagnostic findings were compared to operative results. Results: There was an agreement in findings in 50/50 patients (100%) for selective DSA, in 47/50 (94%) for power mode ultrasound, in 38/50 (76%) for aortic arch DSA, in 31/50 (62%) for color flow duplex ultrasound, and in 5/11 for MR angiography. In contrast to all other methods, ultrasound showed best the true extent of non-calcified atheromatous plaques. In extended vascular calcifications or kinking, however, only parts of the lumen of the vessel could be demonstrated. Conclusion: Power mode ultrasound shows preocclusive stenosis of the ICA in a faster and more simple way than color flow duplex ultrasound and has diagnostic results near to those of selective DSA. It improves preoperative diagnostic screening.
引用
收藏
页码:636 / 640
页数:5
相关论文
共 15 条
[1]   The reliability of color duplex ultrasound in diagnosing total carotid artery occlusion [J].
AbuRahma, AF ;
Pollack, JA ;
Robinson, PA ;
Mullins, D .
AMERICAN JOURNAL OF SURGERY, 1997, 174 (02) :185-187
[2]  
*EUR CAR SURG TRIA, 1995, LANCET, V345, P445
[3]   Reliability and validity of noninvasive imaging of internal carotid artery pseudo-occlusion [J].
Fürst, G ;
Saleh, A ;
Wenserski, F ;
Malms, J ;
Cohnen, M ;
Aulich, A ;
Neumann-Haefelin, T ;
Schroeter, M ;
Steinmetz, H ;
Sitzer, M .
STROKE, 1999, 30 (07) :1444-1449
[4]   CONTRAST-ENHANCED COLOR-CODED DUPLEX SONOGRAPHY OF HIGH-GRADE CAROTID STENOSES [J].
FURST, G ;
SITZER, M ;
HOFER, M ;
STEINMETZ, H ;
HACKLANDER, T ;
MODDER, U .
ULTRASCHALL IN DER MEDIZIN, 1995, 16 (03) :140-144
[5]  
HANKEY GJ, 1996, NEURORADIOLOGY, V38, P25
[6]   Accuracy of duplex sonography before carotid endarterectomy - A comparison with angiography [J].
Hansen, F ;
Bergqvist, D ;
Lindblad, B ;
Lindh, M ;
Matzsch, T ;
Lanne, T .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (03) :331-336
[7]  
Keberle M, 2000, ULTRASCHALL MED, V21, P26
[9]   Colour coding of flow in the intensity-power mode [J].
Krunes, U .
ULTRASCHALL IN DER MEDIZIN, 1997, 18 (03) :143-144
[10]   The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses. [J].
Link, J ;
MullerHulsbeck, S ;
Wesner, F ;
Hopfner, M ;
Schwarzenberg, H ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (01) :30-35