Phantom glucose calibration models from simulated noninvasive human near-infrared spectra

被引:100
作者
Arnold, MA [1 ]
Burmeister, JJ
Small, GW
机构
[1] Univ Iowa, Iowa Adv Technol Labs 230, Dept Chem, Iowa City, IA 52242 USA
[2] Univ Iowa, Iowa Adv Technol Labs 230, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
[3] Ohio Univ, Dept Chem, Ctr Intelligent Chem Insttumentat, Athens, OH 45701 USA
关键词
D O I
10.1021/ac9710801
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The validity of published reports claiming to have successfully measured in vivo blood glucose from noninvasive near-infrared spectra collected in a time-dependent manner is challenged on the basis of results obtained from a phantom glucose spectral data set. An in vitro model is used to simulate noninvasive human near-IR spectra. The phantom glucose data set is created by purposely omitting glucose in these modeled samples. Glucose values are then assigned to successive phantom glucose spectra, and multivariate calibration models are generated for glucose based on partial-least squares regression. As expected, calibration models are incapable of predicting glucose values when the glucose assignments are made randomly. Apparently functional models are obtained, however, when glucose assignments are made in a nonrandom, time-dependent manner. Prediction errors from these nonrandom models are essentially identical to those published by others as evidence of successful noninvasive blood glucose measurements. Chance temporal correlations between assigned glucose concentrations and some uncontrolled experimental parameter are responsible for this apparent model functionality.
引用
收藏
页码:1773 / 1781
页数:9
相关论文
共 26 条
  • [1] AMATO I, 1992, SCIENCE, V258, P892
  • [2] [Anonymous], 1989, MULTIVARIATE CALIBRA
  • [3] Arnold M.A., 1996, HDB CLIN LAB AUTOMAT, P631
  • [4] Non-invasive glucose monitoring
    Arnold, MA
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 46 - 49
  • [5] Burmeister JJ, 1998, PHOTOCHEM PHOTOBIOL, V67, P50, DOI 10.1562/0031-8655(1998)067<0050:PFNBGS>2.3.CO
  • [6] 2
  • [7] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [8] FELWELLING R, 1995, BIOMEDICAL ENG HDB, P1346
  • [9] Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    Fischbacher, C
    Jagemann, KU
    Danzer, K
    Muller, UA
    Papenkordt, L
    Schuler, J
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01): : 78 - 82
  • [10] HAZEN KH, 1995, THESIS U IOWA