Early-warning electrochemical biosensor system for environmental monitoring based on enzyme inhibition

被引:51
作者
Dzyadevych, SV
Soldatkin, AP
Arkhypova, VN
El'skaya, AV
Chovelon, JM
Georgiou, CA
Martelet, C
Jaffrezic-Renault, N
机构
[1] Ecole Cent Lyon, CEGELY, UMR 5005, F-69134 Ecully, France
[2] Natl Acad Sci Ukraine, Inst Mol Biol & Genet, Lab Biomol Elect, UA-03143 Kiev, Ukraine
[3] Univ Lyon 1, CNRS, Lab Applicat Chim Envieonm, F-69622 Villeurbanne, France
[4] Agr Univ Athens, Chem Lab, Athens 11855, Greece
关键词
electrochemical enzyme biosensor; cholinesterases; organophosphorous and carbamate pesticides; enzyme inhibition mechanism;
D O I
10.1016/j.snb.2004.02.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric and conductometric biosensors based on immobilised cholinesterases have been developed. Detection of some organophosphorous pesticides (methyl parathion, methyl paraoxon, ethyl paraoxon, trichlorphon, diisopropyl fluorophosphates) and carbamate pesticide (carbofuran) have been realised through enzyme inhibition mechanisms. Comparison of sensitivity of the biosensor systems developed with that of traditional analytical techniques (high performance liquid chromatography and Lumistox test based on Vibrio fischeri luminescent bacteria) has shown that biosensor measuring procedures are well suited for fast environmental control. Analytical characteristics of the systems created, their advantages and shortcomings are discussed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 19 条
[1]   Multibiosensor based on enzyme inhibition analysis for determination of different toxic substances [J].
Arkhypova, VN ;
Dzyadevych, SV ;
Soldatkin, AP ;
El'skaya, AV ;
Jaffrezic-Renault, N ;
Jaffrezic, H ;
Martelet, C .
TALANTA, 2001, 55 (05) :919-927
[2]   VALIDATION OF AN ENZYMATIC BIOSENSOR WITH LIQUID-CHROMATOGRAPHY FOR PESTICIDE MONITORING [J].
BARCELO, D ;
LACORTE, S ;
MARTY, JL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :334-340
[3]   DETECTION OF ORGANOPHOSPHOROUS PESTICIDES WITH AN IMMOBILIZED CHOLINESTERASE ELECTRODE [J].
DURAND, P ;
NICAUD, JM ;
MALLEVIALLE, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1984, 8 (03) :112-117
[4]  
DZYADEVICH SV, 1994, ELECTROANAL, V6, P752
[5]   Assessment of the toxicity of methyl parathion and its photodegradation products in water samples using conductometric enzyme biosensors [J].
Dzyadevych, SV ;
Soldatkin, AP ;
Chovelon, JM .
ANALYTICA CHIMICA ACTA, 2002, 459 (01) :33-41
[6]   Conductometric formaldehyde sensitive biosensor with specifically adapted analytical characteristics [J].
Dzyadevych, SV ;
Arkhypova, VN ;
Korpan, YI ;
El'skaya, AV ;
Soldatkin, AP ;
Jaffrezic-Renault, N ;
Martelet, C .
ANALYTICA CHIMICA ACTA, 2001, 445 (01) :47-55
[7]   Toxicity of pesticides in wastewater:: a comparative assessment of rapid bioassays [J].
Fernández-Alba, AR ;
Guil, LH ;
López, GM ;
Chisti, Y .
ANALYTICA CHIMICA ACTA, 2001, 426 (02) :289-301
[8]  
JaffrezicRenault N, 1996, SENSOR MATER, V8, P161
[9]  
PATNAIK P, 1997, HDB ENV ANAL CHEM PO, P83
[10]  
PATSKOVSKY SV, 1996, DEVICES EXP TECH, V4, P168