Application of the open path FTIR with COL1SB to measurements of ozone and VOCs in the urban area

被引:20
作者
Hong, DW
Heo, GS
Han, JS
Cho, SY [1 ]
机构
[1] Inha Univ, Dept Environm Engn, Inchon 402751, South Korea
[2] Korea Res Inst Stds & Sci, Div Chem Metrol & Mat Evaluat, Taejon, South Korea
[3] Natl Inst Environm Res, Div Atmospher Chem, Inchon, South Korea
关键词
open-path Fourier transform infrared spectroscopy; VOCs; water vapor pressure; ambient monitoring; site specific spectrum;
D O I
10.1016/j.atmosenv.2004.06.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The COnstrained L1-norm minimization with the Synthetic Background generation method (COL1SB) is newly developed open-path FTIR analysis software, designed to efficiently handle chemical interferences and to systematically generate background spectra. The performance of COL1SB was evaluated mainly against artificially generated field spectra. The present paper aims at application of COL1SB to ambient monitoring. In order to satisfy low detection limit requirements of ambient monitoring, COL1SB was further improved to accurately determine path averaged water vapor pressures, to dynamically select appropriate spectral bands, and to use site specific background spectra. The modified COL1SB was applied to measure ozone, ammonia, methane, carbon monoxide, and 26 VOC species in the park located at the urban area from 12:00 a.m., 25 May to 12:00 a.m., 26 May 2000. The open-path FTIR measurements for ozone, water vapor, alkane concentrations compared very well with those by sampling methods both in magnitudes and in diurnal variations. Furthermore, the detection rates of VOCs were considerably enhanced such that the detection rates based on the correlation coefficients appeared to be above 50% for 12 species out of 16 representative chemical species. Especially ethylene and isoprene, chemically reactive olefins, had high detection rates exceeding 80% despite of their low concentrations. These detection rates by COL1SB are 2-5 times higher than those derived by the conventional CLS method in the previous work (SPIE Conference on Environmental Monitoring and Remediation Technologies SPIE (1998) 3534, 140). (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5567 / 5576
页数:10
相关论文
共 14 条
[1]   Multi-pollutant concentration measurements around a concentrated swine production facility using open-path FTIR spectrometry [J].
Childers, JW ;
Thompson, EL ;
Harris, DB ;
Kirchgessner, DA ;
Clayton, M ;
Natschke, DF ;
Phillips, WJ .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (11) :1923-1936
[2]   Synthetic calibration and quantitative analysis of gas-phase FT-IR spectra [J].
Griffith, DWT .
APPLIED SPECTROSCOPY, 1996, 50 (01) :59-70
[3]  
HAN JS, 2000, P 31 M KOR SOC ATM E, P299
[4]  
HAN JS, 2000, P 31 M KOR SOC ATM E, P297
[5]   Methane and carbon dioxide emissions from Shan-Chu-Ku landfill site in northern Taiwan [J].
Hegde, U ;
Chang, TC ;
Yang, SS .
CHEMOSPHERE, 2003, 52 (08) :1275-1285
[6]  
HEO GS, 2000, P 31 M KOR SOC ATM E, P304
[7]   Improved methods for performing multivariate analysis and deriving background spectra in atmospheric open-path FT-IR monitoring [J].
Hong, DW ;
Cho, SY .
APPLIED SPECTROSCOPY, 2003, 57 (03) :299-308
[8]  
KAGANN RH, 1998, SPIE C ENV MON REM T, V3534, P140
[9]   DEVELOPMENT OF CALIBRATION STANDARDS FOR FOURIER-TRANSFORM INFRARED SPECTROMETER IN CONTINOUS MONITORING OF INCINERATOR EMISSIONS [J].
MAO, ZX ;
DEMIRGIAN, JC .
WASTE MANAGEMENT, 1995, 15 (03) :233-241
[10]  
Perry SH, 1995, AWMA C OPT REM SENS, V2883, P333