Use of time-resolved lanthanide-sensitized luminescence for the kinetic determination of p-aminobenzoic acid

被引:23
作者
Panadero, S [1 ]
Gomez-Hens, A [1 ]
Perez-Bendito, D [1 ]
机构
[1] Univ Cordoba, Fac Sci, Dept Analyt Chem, E-14004 Cordoba, Spain
关键词
kinetic method; p-aminobenzoic acid; lanthanide-sensitized luminescence; stopped-flow technique; pharmaceutical samples;
D O I
10.1016/S0039-9140(97)00169-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lanthanide-sensitized luminescence was for the first time used to develop a simple kinetic method for the determination of p-aminobenzoic acid. The method is based on the formation of a complex with terbium(III) in the presence of trioctylphosphine oxide as synergistic agent and Triton X-100 as micellar medium. The high initial rate of the complex formation required the use of stopped-flow mixing technique in order to make kinetic measurements which, in addition, allows the method to be automated. Its analytical features compare very favourably with those described by using solid-surface room temperature phosphorescence in terms of rapidity, precision and selectivity. The initial rate is obtained within only 0.2 s after the reactants are mixed, which allows ready application of the proposed method to routine analyses. The calibration graph is linear over the range 0.08-4.0 mu g ml(-1) p-aminobenzoic acid and the detection limit is 0.02 mu g ml(-1). The relative standard deviation is close to 2%. The kinetic methodology avoids the effect of the sample matrix allowing the direct determination of this compound in pharmaceutical preparations. Analytical recoveries ranged between 98.6 and 113.0%. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:829 / 834
页数:6
相关论文
共 18 条
[1]   STUDIES OF CYCLODEXTRIN-ENHANCED ROOM-TEMPERATURE PHOSPHORESCENCE [J].
ALAK, AM ;
CONTOLINI, N ;
VO-DINH, T .
ANALYTICA CHIMICA ACTA, 1989, 217 (01) :171-176
[2]  
ALVAREZCOQUE MCG, 1988, ANAL CHIM ACTA, V204, P247
[3]   FLOW-INJECTION FOR CONTINUOUS SAMPLE INTRODUCTION IN SOLID-SUBSTRATE ROOM-TEMPERATURE PHOSPHORESCENCE [J].
CAMPIGLIA, AD ;
BERTHOD, A ;
WINEFORDNER, JD .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :289-293
[4]  
HURTUBISE RJ, 1990, PHOSPHORIMETRY THEOR
[5]   COMPARATIVE-EVALUATION OF 2 SUBSTRATES FOR URINARY DETERMINATION OF PARA-AMINOBENZOIC ACID BY ROOM-TEMPERATURE PHOSPHORIMETRY [J].
KARNES, HT ;
SCHULMAN, SG ;
WINEFORDNER, JD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :257-262
[6]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+
[7]   PHARMACEUTICAL DETERMINATION BY DERIVATIZATION - ROOM-TEMPERATURE PHOSPHORESCENCE [J].
LONG, WJ ;
NORIN, RC ;
SU, SY .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2873-2877
[8]   VERSATILE AUTOMATIC STOPPED-FLOW SYSTEM FOR ROUTINE ANALYSIS [J].
LORIGUILLO, A ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1987, 199 :29-40
[9]   REDUCTION OF BACKGROUND EMISSION IN ROOM-TEMPERATURE PHOSPHORESCENCE [J].
MCALEESE, DL ;
DUNLAP, RB .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :600-601
[10]   A SAMPLE-DRYING TECHNIQUE FOR ROOM-TEMPERATURE PHOSPHORESCENCE [J].
MCALEESE, DL ;
DUNLAP, RB .
ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) :431-436