Percutaneous transcatheter aortic disc valve prosthesis implantation:: A feasibility study

被引:43
作者
Sochman, J [1 ]
Peregrin, JH [1 ]
Pavcnik, D [1 ]
Timmermans, H [1 ]
Rösch, J [1 ]
机构
[1] Inst Clin & Expt Med, Dept Cardiol, Prague 14021 4, Czech Republic
关键词
disc valve prosthesis; aortic regurgitation; catheterization technique;
D O I
10.1007/s002700010060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Over the past 30 years there have been experimental efforts at catheter-based management of aortic valve regurgitation with the idea of extending treatment to nonsurgical candidates. A new catheter-based aortic valve design is described. Methods: The new catheter-delivered valve consists of a stent-based valve cage with locking mechanism and a prosthetic flexible tilting Valve disc. The valve cage is delivered first followed by deployment and locking of the disc. In acute experiments, valve implantation was done in four dogs. Results: Valve implantation was successful in all four animals. The implanted valve functioned well for the duration of the experiments (up to 3 hr). Conclusion: The study showed the implantation feasibility and short-term function of the tested catheter-based aortic disc valve. Further experimental studies are warranted.
引用
收藏
页码:384 / 388
页数:5
相关论文
共 17 条
  • [1] TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS
    ANDERSEN, HR
    KNUDSEN, LL
    HASENKAM, JM
    [J]. EUROPEAN HEART JOURNAL, 1992, 13 (05) : 704 - 708
  • [2] BORETOS JW, 1977, Patent No. 4056854
  • [3] DAVIES H, 1965, LANCET, V1, P250
  • [4] PARTIAL AND COMPLETE PROSTHESES IN AORTIC INSUFFICIENCY
    HARKEN, DE
    SOROFF, HS
    TAYLOR, WJ
    LEFEMINE, AA
    GUPTA, SK
    LUNZER, S
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1960, 40 (06) : 744 - 762
  • [5] HILBERT SL, 1987, J THORAC CARDIOV SUR, V94, P419
  • [6] HUFNAGEL CA, 1954, SURGERY, V35, P673
  • [7] HUFNAGEL CA, 1953, B GEORGETOWN U MED C, V6, P3
  • [8] LO HB, 1988, T AM SOC ART INT ORG, V34, P839
  • [9] BALLOON CATHETER WITH CHECK VALVES FOR EXPERIMENTAL RELIEF OF ACUTE AORTIC REGURGITATION
    MATSUBARA, T
    YAMAZOE, M
    TAMURA, Y
    OHSHIMA, M
    YAMAZAKI, Y
    SUZUKI, M
    IZUMI, T
    SHIBATA, A
    [J]. AMERICAN HEART JOURNAL, 1992, 124 (04) : 1002 - 1008
  • [10] Transluminal aortic valve placement - A feasibility study with a newly designed collapsible aortic valve
    Moazami, N
    Bessler, M
    Argenziano, M
    Choudhri, AF
    Cabreriza, SE
    Allendorf, JDF
    Rose, EA
    Oz, MC
    [J]. ASAIO JOURNAL, 1996, 42 (05) : M381 - M385