Amperometric sensor for L-ascorbic acid determination based on MnO2 bulk modified screen printed electrode

被引:46
作者
Turkusic, E
Milicevic, V
Tahmiscija, H
Vehabovic, M
Basic, S
Amidzic, V
机构
[1] Univ Sarajevo, Fac Sci, Dept Chem, Sarajevo 71000, Bosnia & Herceg
[2] Univ Sarajevo, Fac Dent, Sarajevo 71000, Bosnia & Herceg
[3] Pharmaceut Co Bosnalijek Sarajevo, Sarajevo 71000, Bosnia & Herceg
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 368卷 / 05期
关键词
D O I
10.1007/s002160000487
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple biosensor constructed by bulk-modification of carbon ink with manganese dioxide as a mediator was investigated for its ability to serve as amperometric detector for L-ascorbic acid in hydrodynamic mode. The sensor could be operated at pH 5.0 (0.05 M phosphate buffer) and exhibited excellent reproducibility and stability. Optimization of measurement parameters such as applied working potential and pH value were studied in detail. The screen printed electrode exhibited a linear amperometric increase with the concentration of L-ascorbic acid from 50 mg L-1 to 250 mg L-1 and gave a (LOD = 3 sigma) detection limit of 0.2 mg L-1 (1.172 mu mol L-1). The manganese dioxide modified screen printed electrode shows long term stability.
引用
收藏
页码:466 / 470
页数:5
相关论文
共 8 条
[1]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[2]   DETERMINATION OF ASCORBIC-ACID BY DIFFERENTIAL PULSE VOLTAMMETRY [J].
LECHIEN, A ;
VALENTA, P ;
NURNBERG, HW ;
PATRIARCHE, GJ .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 311 (02) :105-108
[3]  
POURBAIX M, 1974, ATLAS ELECTROCHEMICA, P290
[4]   Catalytic oxidation of ascorbic acid by some ferrocene derivative mediators at the glassy carbon electrode. Application to the voltammetric resolution of ascorbic acid and dopamine in the same sample [J].
PournaghiAzar, MH ;
Ojani, R .
TALANTA, 1995, 42 (12) :1839-1848
[5]   Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis [J].
Schachl, K ;
Alemu, H ;
Kalcher, K ;
Jezkova, J ;
Svancara, I ;
Vytras, K .
ANALYST, 1997, 122 (09) :985-989
[6]  
SCHACHL K, 1998, THESIS K FRANZENS U
[7]  
SCHACHL K, 2000, IN PRESS SENSOR AC B
[8]   ELECTROCHEMICAL OXIDATION OF L-ASCORBIC-ACID AT THE GRAPHITE ELECTRODE AND ITS MONITORING BY A THICK-FILM GRAPHITE SENSOR ASSEMBLY [J].
XING, XK ;
TAN, TC ;
SHAO, M ;
LIU, CC .
ELECTROANALYSIS, 1992, 4 (02) :191-197