Immunoassay of the MRSA-related toxic protein, leukocidin, with scanning electrochemical microscopy

被引:60
作者
Kasai, S [1 ]
Yokota, A
Zhou, HF
Nishizawa, M
Niwa, K
Onouchi, T
Matsue, T
机构
[1] Tohoku Univ, Grad Sch Engn, Dept Biomol Engn, Sendai, Miyagi 9808579, Japan
[2] Matsushita Seiko Co Ltd, Kasugai, Aichi 4868522, Japan
关键词
D O I
10.1021/ac000895y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Scanning electrochemical microscopy (SECM) was applied to the immunoassay of leukocidin, which is a toxic protein produced by methicillin-resistant Staphylococcus aureus (MRSA), with the intention of developing and early diagnostic for MRSA infection. An antibody-chip for leukocidin was prepared by self-assembling of anti-leukocidin on a protein A-coated glass substrate. A sample solution containing leukocidin was spotted onto the antibody-chip, followed by labeling with horseradish peroxidase (HRP) via a sandwich method. The reduction current of the oxidized form of ferrocenylmethanol generated by the HRP reaction was monitored to view SECM images of the spot of captured leukocidin, The amplitude of reduction current depended on the concentrations of sample solutions used for making spots. This SECM-based immunoassay detects as low as 5.25 pg mL(-1) leukocidin.
引用
收藏
页码:5761 / 5765
页数:5
相关论文
共 36 条
[1]  
Bard A. J., 1994, ELECTROANALYTICAL CH, V18
[2]  
COUSINO MA, 1997, ANAL CHEM NEWS FEATU, pA544
[3]   An immunomagnetic electrochemical sensor based an a perfluorosulfonate-coated screen-printed electrode for the determination of 2,4-dichlorophenoxyacetic acid [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2571-2577
[4]  
DUBROVSKY T, 1995, SENSOR ACTUAT B-CHEM, V404, P1
[5]   SCANNING ELECTROCHEMICAL MICROSCOPY [J].
ENGSTROM, RC ;
PHARR, CM .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :A1099-+
[6]   ELECTROCHEMICAL DETECTION OF SINGLE MOLECULES [J].
FAN, FRF ;
BARD, AJ .
SCIENCE, 1995, 267 (5199) :871-874
[7]   STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY [J].
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :1321-&
[8]   SCANNING ELECTROCHEMICAL MICROSCOPY .24. ENZYME ULTRAMICROELECTRODES FOR THE MEASUREMENT OF HYDROGEN-PEROXIDE AT SURFACES [J].
HORROCKS, BR ;
SCHMIDTKE, D ;
HELLER, A ;
BARD, AJ .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3605-3614
[9]   SCANNING ELECTROCHEMICAL MICROSCOPY .19. ION-SELECTIVE POTENTIOMETRIC MICROSCOPY [J].
HORROCKS, BR ;
MIRKIN, MV ;
PIERCE, DT ;
BARD, AJ ;
NAGY, G ;
TOTH, K .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1213-1224
[10]   EVIDENCE FOR A CLONAL ORIGIN OF METHICILLIN RESISTANCE IN STAPHYLOCOCCUS-AUREUS [J].
KREISWIRTH, B ;
KORNBLUM, J ;
ARBEIT, RD ;
EISNER, W ;
MASLOW, JN ;
MCGEER, A ;
LOW, DE ;
NOVICK, RP .
SCIENCE, 1993, 259 (5092) :227-230