A new Diamentor for measuring kerma-area product and air-kerma simultaneously

被引:17
作者
Gfirtner, H [1 ]
Stieve, FE
Wild, J
机构
[1] Klinikum Passau, Passau, Germany
[2] Bundesamt Strahlenschutz, Inst Strahlenhyg, Munich, Germany
关键词
diagnostic radiology; dose area product; air kerma; patient radiation protection;
D O I
10.1118/1.598109
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The new M4KDK Diamentor (PTW-Freiburg) for measuring the air-kerma-area product (KAP) and air kerma (AK) simultaneously was evaluated. The special design of the Diamentor chamber influences the variation of the calibration factor with respect to the field size somewhat differently to what is the case with the classic Diamentor. It is therefore recommended that calibration be performed for a larger held size. If the M4KDK Diamentor is calibrated for a field size of 3.8 cmx3.8 cm (at the chamber), an uncertainty in the KAP value of better than 15% for all field sizes used in practice, and an uncertainty in the AK value of better than 15% for a field size larger than the calibration field, can be expected. The influence of backscattered radiation on the calibration factor is equivalent to that for the classic Diamentor chamber. The variation in response in accordance with tube potential, is also comparable with that of the classic Diamentor. Dramatic changes in response have to be expected if additional filters are introduced in close proximity to the Diamentor chamber. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1954 / 1959
页数:6
相关论文
共 21 条
[1]  
*AM COLL RAD COMM, 1992, P ACR FDA WORKSH FLU
[2]   ROUTINE DOSE RECORDING IN DIAGNOSTIC RADIOLOGY [J].
ARDRAN, GM ;
CROOKS, HE .
BRITISH JOURNAL OF RADIOLOGY, 1963, 36 (429) :689-694
[3]  
ARNAL M L, 1961, Fortschr Geb Rontgenstr Nuklearmed, V95, P323
[4]   DETERMINATION OF INTEGRAL ABSORBED DOSE FROM EXPOSURE MEASUREMENTS [J].
CARLSSON, C .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1963, 1 (06) :433-&
[5]   INTEGRAL ABSORBED DOSES IN ROENTGEN DIAGNOSTIC PROCEDURES .I. DOSEMETER [J].
CARLSSON, C .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1965, 3 (04) :310-&
[6]   ENERGY IMPARTED TO THE PATIENT IN DIAGNOSTIC-RADIOLOGY - CALCULATION OF CONVERSION FACTORS FOR DETERMINING THE ENERGY IMPARTED FROM MEASUREMENTS OF THE AIR COLLISION KERMA INTEGRATED OVER BEAM AREA [J].
CARLSSON, GA ;
CARLSSON, CA ;
PERSLIDEN, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1329-1341
[7]  
*EUR COMM SCI RES, 1996, EUR GUID QUAL CRIT D
[8]   ESTIMATION OF EFFECTIVE DOSE FROM DOSE-AREA PRODUCT MEASUREMENTS FOR BARIUM MEALS AND BARIUM ENEMAS [J].
HART, D ;
WALL, BF .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :485-489
[9]  
*ICRP, 1970, PUBL ICRP, V16
[10]  
*IEC, 1977, 580 IEC