Lithium determination in artificial serum using flow injection systems with a selective solid-state tubular electrode based on NASICON membranes

被引:26
作者
Cretin, M
Alerm, L
Bartroli, J
Fabry, P
机构
[1] ECOLE NATL SUPER ELECTROCHIM & ELECTROME GRENOBLE,CNRS UMR 5631,F-38402 ST MARTIN DHER,FRANCE
[2] ECOLE NATL SUPER ELECTROCHIM & ELECTROME GRENOBLE,UJFG,F-38402 ST MARTIN DHER,FRANCE
[3] UNIV AUTONOMA BARCELONA,DEPT QUIM,GRP SENSORS & BIOSENSORS,E-08193 BELLATERRA,SPAIN
关键词
lithium analysis; flow injection; ion selective electrode; Li+-NASICON; artificial serum;
D O I
10.1016/S0003-2670(97)00310-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The main objective of this work is the determination of lithium in the serum in the concentrations found in the plasma and the urine of patients being treated with lithium salts. Results of measurements under quiescent conditions and with flow injection analysis are compared. The solid-state tubular lithium sensor evaluated is based on conductive ceramics. A flow injection analysis (FIA) system using Li+-NASICON as the sensitive membrane and a BaCl2 0.1 M solution as carrier shows several advantages such as a good sampling frequency (20 samples h(-1)), a low detection limit (logarithmic range from 5x10(-4) M) and a near-Nernstian sensitivity (57 mV/decade). Lithium measurements in artificial serum, using 0.1 M BaCl2 as a carrier solution, provided better results. Lithium determination in urine is possible because the usual concentration (10-30 mM) is in the logarithmic response range of the sensor. Concerning blood analysis (from 7 x 10(-4) to 2 x 10(-3) M in Li), the non-Nernstian response of the system in the lithium therapy concentration range does not seem to be a major problem because of the systematic calibration possibilities when using I;LA instrumentation.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 23 条
[1]   FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
MARTINEZFABREGAS, E .
ANALYST, 1989, 114 (11) :1443-1447
[2]   SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS [J].
ALONSO, J ;
BARTROLI, J ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1986, 179 :503-508
[3]   CONDUCTIVE EPOXY-GRAPHITE COMPOSITE AS A SOLID INTERNAL REFERENCE IN A NASICON-BASED SODIUM ION-SELECTIVE ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
BARTROLI, J ;
ALERM, L ;
FABRY, P ;
SIEBERT, E .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :102-108
[4]  
CHARAZAC P, 1983, PSYCHOL MED, V15, P781
[5]   STUDY OF LI1+XALXTI2-X(PO4)(3) FOR LI+ POTENTIOMETRIC SENSORS [J].
CRETIN, M ;
FABRY, P ;
ABELLO, L .
JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 1995, 15 (11) :1149-1156
[6]  
Cretin M, 1995, ANN CHIM-SCI MAT, V20, P433
[7]  
CRETIN M, UNPUB J EUR CERAM SO
[8]  
CRETIN M, 1996, THESIS I NAT POLYTEC
[9]  
FABRY P, 1988, SENSOR ACTUATOR, V9, P1
[10]  
GADZEKPO VPY, 1986, ION SEL ELECTRODE R, V8, P173