Postprandial insulin profiles with implantable pump therapy may explain decreased frequency of severe hypoglycemia, compared with intensive subcutaneous regimens, in insulin-dependent diabetes mellitus patients

被引:53
作者
Nathan, DM
Dunn, FL
Bruch, J
McKitrick, C
Larkin, M
Haggan, C
LavinTompkins, J
Norman, D
Rogers, D
Simon, D
机构
[1] MASSACHUSETTS GEN HOSP, DEPT MED, BOSTON, MA 02114 USA
[2] MASSACHUSETTS GEN HOSP, DEPT PSYCHOL, BOSTON, MA USA
[3] HARVARD UNIV, SCH MED, BOSTON, MA USA
[4] DUKE UNIV, MED CTR, DIV METAB ENDOCRINOL & NUTR, DURHAM, NC USA
关键词
D O I
10.1016/S0002-9343(97)89516-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PURPOSE: TO examine the mechanism of the decreased frequency of severe hypoglycemia with implantable pump therapy compared with subcutaneous intensive therapy. PATIENTS AND METHODS: Eight subjects with insulin-dependent diabetes mellitus (IDDM), enrolled in an implantable insulin pump study, were admitted to the General Clinical Research Center and on 2 separate days were given either a dose of preprandial insulin chosen to maintain normoglycemia for a standard (450 kcal, 50% carbohydrate) breakfast or 1.75 times the dose. The two doses were administered subcutaneously (by syringe or with an external pump) during one inpatient admission and by implantable pump (intraperitoneally, n = 6; or intravenously, n = 2) during a separate admission. Blood glucose, plasma-free insulin, and neurocognitive function were measured for 4 hours after the meal. RESULTS: Subcutaneous administration resulted in 7 episodes of hypoglycemia (2 with the usual dose and 5 with the 1.75-fold dose), defined as blood glucose less than 50 mg/dL; implantable pump treatment resulted in only 2 episodes, both with the 1.75-fold dose (P <0.05, Fisher's two-tailed test for implantable versus subcutaneous). Compared with subcutaneous delivery, implantable pump therapy provided significantly lower insulin levels during the final 2 hours after administration of the usual dose and the 1.75-fold dose (P <0.005). In addition to the decreased frequency of hypoglycemia, implantable pump therapy resulted in significantly lower area under the glycemia curve during the first 120 minutes with the 1.75-fold dose compared with subcutaneous administration. CONCLUSIONS: The lower frequency of severe hypoglycemia with intensive therapy administered by implantable pump therapy is explained by the more rapid clearance of insulin delivered intraperitoneally or intravenously compared with intensive subcutaneous injection regimens. The lower frequency of severe hypoglycemia with implantable pump therapy compared with subcutaneous therapy demonstrated in clinical trials is confirmed by this study, in which we attempted to induce hypoglycemia.
引用
收藏
页码:412 / 417
页数:6
相关论文
共 27 条
[1]   CONTROL OF BLOOD-GLUCOSE IN EXPERIMENTAL DIABETES BY MEANS OF A TOTALLY IMPLANTABLE INSULIN INFUSION DEVICE [J].
BLACKSHEAR, PJ ;
ROHDE, TD ;
GROTTING, JC ;
DORMAN, FD ;
PERKINS, PR ;
VARCO, RL ;
BUCHWALD, H .
DIABETES, 1979, 28 (07) :634-639
[2]   MONOMERIC INSULINS AND THEIR EXPERIMENTAL AND CLINICAL IMPLICATIONS [J].
BRANGE, J ;
OWENS, DR ;
KANG, S ;
VOLUND, A .
DIABETES CARE, 1990, 13 (09) :923-954
[3]   DISRUPTIVE EFFECTS OF ACUTE HYPOGLYCEMIA ON SPEED OF COGNITIVE AND MOTOR-PERFORMANCE [J].
COX, DJ ;
GONDERFREDERICK, LA ;
SCHROEDER, DB ;
CRYER, PE ;
CLARKE, WL .
DIABETES CARE, 1993, 16 (10) :1391-1393
[4]  
DCCT Res Grp, 1991, AM J MED, V90, P450, DOI 10.1016/0002-9343(91)80085-Z
[5]  
DCCT Res Grp, 1990, DIABETES CARE, V13, P427
[6]  
Diabetes Control and Complications Trial Research Group, 1993, NEW ENGL J MED, V329, P978
[8]   IMPORTANCE OF TIMING OF PREPRANDIAL SUBCUTANEOUS INSULIN ADMINISTRATION IN THE MANAGEMENT OF DIABETES-MELLITUS [J].
DIMITRIADIS, GD ;
GERICH, JE .
DIABETES CARE, 1983, 6 (04) :374-377
[9]  
Eaton R P, 1978, Diabetes Care, V1, P40, DOI 10.2337/diacare.1.1.40
[10]   COMPARISON OF SUBCUTANEOUS SOLUBLE HUMAN INSULIN AND INSULIN ANALOGS (ASPB9,GLUB27-ASPB10-ASPB28) ON MEAL-RELATED PLASMA-GLUCOSE EXCURSIONS IN TYPE-I DIABETIC SUBJECTS [J].
KANG, S ;
CREAGH, FM ;
PETERS, JR ;
BRANGE, J ;
VOLUND, A ;
OWENS, DR .
DIABETES CARE, 1991, 14 (07) :571-577