Quantitative ocular tests for myasthenia gravis: a comparative review with detection theory analysis

被引:17
作者
Barton, JJS
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Neurol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Ophthalmol, Boston, MA 02215 USA
关键词
myasthenia gravis; saccades; intra-ocular pressure; optokinetic nystagmus; detection theory;
D O I
10.1016/S0022-510X(97)00265-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Many reports in the literature describe a variety of ocular signs in myasthenia gravis. To determine the utility of laboratory recordings of ocular signs in the evaluation for myasthenia, we reviewed all previous studies of quantitative measures of eye movements or intra-ocular pressures. We selected those studies with data presented for both myasthenic and non-myasthenic ocular palsies. Signal detection theory was used to evaluate the discriminative power of each variable. The characteristics of saccades and quick phases of optokinetic nystagmus at the start of recording were poor at distinguishing between myasthenic and non-myasthenic palsies, except when the comparison was solely between myasthenia and chronic progressive external ophthalmoplegia. The effects of fatigue on saccadic parameters were also not discriminative, though there was insufficient data to evaluate this adequately. Changes induced by edrophonium in the amplitude or peak velocity of saccades or optokinetic quick phases were good diagnostic tests, retaining high sensitivities when criteria were set to yield a specificity of 95%, Most of these parameters were less efficient as screening tests, with modest specificities when criteria were set to yield a sensitivity of 95%. The change in optokinetic quick phase amplitude recorded by infrared oculography was the best test, with ideal characteristics of 97% specificity and sensitivity at a criterion of zero change. This analysis suggests that eye movement recordings of saccades or optokinetic nystagmus have potential as useful and inexpensive tests for myasthenia, and warrant further study. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:104 / 114
页数:11
相关论文
共 37 条
[1]   OVERLAPPING SACCADES AND GLISSADES ARE PRODUCED BY FATIGUE IN SACCADIC EYE-MOVEMENT SYSTEM [J].
BAHILL, AT ;
STARK, L .
EXPERIMENTAL NEUROLOGY, 1975, 48 (01) :95-106
[2]   SACCADE FATIGUE AND RESPONSE TO EDROPHONIUM FOR DIAGNOSIS OF MYASTHENIA-GRAVIS [J].
BALOH, RW ;
KEESEY, JC .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1976, 274 (MAY28) :631-641
[3]   EFFECTS OF EDROPHONIUM ON SACCADIC VELOCITY IN NORMAL SUBJECTS AND MYASTHENIC AND NONMYASTHENIC OCULAR PALSIES [J].
BARTON, JJS ;
HUAMAN, AG ;
SHARPE, JA .
ANNALS OF NEUROLOGY, 1994, 36 (04) :585-594
[4]   SACCADIC DURATION AND INTRASACCADIC FATIGUE IN MYASTHENIC AND NONMYASTHENIC OCULAR PALSIES [J].
BARTON, JJS ;
JAMA, A ;
SHARPE, JA .
NEUROLOGY, 1995, 45 (11) :2065-2072
[5]  
BARTON JJS, 1995, INVEST OPHTH VIS SCI, V36, P1566
[6]  
BOGHEN D, 1976, UNION MED CAN, V105, P932
[7]   OCULAR MYASTHENIA - EVALUATION OF TENSILON TONOGRAPHY AND ELECTRONYSTAGMOGRAPHY AS DIAGNOSTIC TESTS [J].
CAMPBELL, MJ ;
SIMPSON, E ;
CROMBIE, AL ;
WALTON, JN .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1970, 33 (05) :639-&
[8]   THE EDROPHONIUM-HESS SCREEN TEST IN THE DIAGNOSIS OF OCULAR MYASTHENIA-GRAVIS [J].
COLL, GE ;
DEMER, JL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 114 (04) :489-493
[9]   CLINICAL, PATHOLOGICAL, HLA-ANTIGEN AND IMMUNOLOGICAL EVIDENCE FOR DISEASE HETEROGENEITY IN MYASTHENIA-GRAVIS [J].
COMPSTON, DAS ;
VINCENT, A ;
NEWSOMDAVIS, J ;
BATCHELOR, JR .
BRAIN, 1980, 103 (SEP) :579-601
[10]   OCULAR MYASTHENIA - DIAGNOSTIC AND THERAPEUTIC PROBLEMS [J].
EVOLI, A ;
TONALI, P ;
BARTOCCIONI, E ;
LOMONACO, M .