Estimating biozone hydraulic conductivity in wastewater soil-infiltration systems using inverse numerical modeling

被引:28
作者
Bumgarner, Johnathan R.
McCray, John E. [1 ]
机构
[1] Colorado Sch Mines, Hydrol Sci & Engn Program, Environm Sci & Engn Div, Golden, CO 80401 USA
[2] Univ Texas, Dept Geol Sci, Austin, TX 78712 USA
关键词
wastewater treatment; soil; infiltration; mathematical modeling; biozone; hydraulic conductivity; septic tank;
D O I
10.1016/j.watres.2007.02.040
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During operation of an onsite wastewater treatment system, a low-permeability biozone develops at the infiltrative surface (IS) during application of wastewater to soil. Inverse numerical-model simulations were used to estimate the biozone saturated hydraulic conductivity (K-biozone) under variably saturated conditions for 29 wastewater infiltration test cells installed in a sandy loam field soil. Test cells employed two loading rates (4 and 8 cm/ day) and 3 IS designs: open chamber, gravel, and synthetic bundles. The ratio of Kbiozone to the saturated hydraulic conductivity of the natural soil (K-s) was used to quantify the reductions in the IS hydraulic conductivity. A smaller value Of K-biozone/K-s, reflects a greater reduction in hydraulic conductivity. The IS hydraulic conductivity was reduced by 1-3 orders of magnitude. The reduction in IS hydraulic conductivity was primarily influenced by wastewater loading rate and IS type and not by the K-s of the native soil. The higher loading rate yielded greater reductions in IS hydraulic conductivity than the lower loading rate for bundle and gravel cells, but the difference was not statistically significant for chamber cells. Bundle and gravel cells exhibited a greater reduction in IS hydraulic conductivity than chamber cells at the higher loading rates, while the difference between gravel and bundle systems was not statistically significant. At the lower rate, bundle cells exhibited generally lower Kbiozone/Ks values, but not at a statistically significant level, while gravel and chamber cells were statistically similar. Gravel cells exhibited the greatest variability in measured values, which may complicate design efforts based on Kbiozone evaluations for these systems. These results suggest that chamber systems may provide for a more robust design, particularly for high or variable wastewater infiltration rates. (C) 2007 Published by Elsevier Ltd.
引用
收藏
页码:2349 / 2360
页数:12
相关论文
共 28 条
[1]   Temporal changes in hydraulic conductivity of sand porous media biofilters during wastewater infiltration due to biomat formation [J].
Beach, DNH ;
McCray, JE ;
Lowe, KS ;
Siegrist, RL .
JOURNAL OF HYDROLOGY, 2005, 311 (1-4) :230-243
[2]   Numerical modeling of unsaturated flow in wastewater soil absorption systems [J].
Beach, DNH ;
McCray, JE .
GROUND WATER MONITORING AND REMEDIATION, 2003, 23 (02) :64-72
[3]   Efffluent flux prediction in variably saturated soil zones within a septic tank-soil absorption trench [J].
Beal, Cara D. ;
Gardner, Ted ;
Rassam, David W. ;
Vieritz, Alison M. ;
Menzies, Neal W. .
AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2006, 44 (07) :677-686
[4]   Process, performance, and pollution potential: A review of septic tank-soil absorption systems [J].
Beal, CD ;
Gardner, EA ;
Menzies, NW .
AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2005, 43 (07) :781-802
[5]  
BUMGARNER JR, 2005, THESIS U TEXAS AUSTI
[6]   DEVELOPING JOINT PROBABILITY-DISTRIBUTIONS OF SOIL-WATER RETENTION CHARACTERISTICS [J].
CARSEL, RF ;
PARRISH, RS .
WATER RESOURCES RESEARCH, 1988, 24 (05) :755-769
[7]  
HELSEL DR, 1991, STAT METHOD WATER RE
[8]  
HOPMANS JW, 1999, CHARACTERIZATION MEA
[9]   Calibration of Richards' and convection-dispersion equations to field-scale water flow and solute transport under rainfall conditions [J].
Jacques, D ;
Simunek, J ;
Timmerman, A ;
Feyen, J .
JOURNAL OF HYDROLOGY, 2002, 259 (1-4) :15-31
[10]  
JONES JOE H., 1965, SOIL SCI, V99, P301