Dynamic US of the anterior band of the ulnar collateral ligament of the elbow in asymptomatic major league baseball pitchers

被引:148
作者
Nazarian, LN
McShane, JM
Ciccotti, MG
O'Kane, PL
Harwood, MI
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Div Ultrasound, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, Dept Family Med, Div Sports Med, Philadelphia, PA 19107 USA
[3] Thomas Jefferson Univ Hosp, Dept Orthoped Surg, Philadelphia, PA 19107 USA
关键词
athletes and athletics; athletic injuries; elbow; injuries; US; ligaments;
D O I
10.1148/radiol.2271020288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To determine whether dynamic ultrasonography (US) can reveal abnormalities of the anterior band of the ulnar collateral ligament (UCL) of the elbow in asymptomatic major league professional baseball players. MATERIALS AND METHODS: US was performed in 26 asymptomatic major league professional baseball pitchers before spring training. Images were obtained in both pitching and nonpitching arms with a multifrequency 13-MHz linear-array transducer. The thickness of the anterior band of the UCL and the width of the joint it spans (the ulnohumeral joint) were measured with the elbow at 30degrees of flexion, both at rest and with valgus stress. The thickness of the anterior band of the UCL and the width of the joint space were compared for pitching and nonpitching arms by using the Student t test. The prevalence of hypoechoic areas and calcifications within the anterior band of the UCL in pitching and nonpitching arms was compared by using the McNemar test. The average time of the US examinations was recorded. RESULTS: At rest, the mean thickness (+/- 1 SD) of the anterior band of the UCL was 6.3 mm 1.1 in pitching arms and 5.3 mm +/- 1.0 in nonpitching arms. This difference was statistically significant (P < .01). With stress, the anterior band thickness was 6.3 mm +/- 1.4 in the pitching arms and 4.8 mm +/- 0.9 in the nonpitching arms (P < .001). The joint space width at rest was 2.8 mm +/- 1.0 in the pitching arms and 2.5 mm +/- 0.7 in the nonpitching arms (not statistically significant). When stress was applied, however, the joint space width was significantly greater in the pitching arms than in the nonpitching arms (4.2 mm +/- 1.5 vs 3 mm 1.0, respectively; P < .01). Hypoechoic foci within the anterior band of the UCL were seen in 18 of 26 (69%) pitching arms and three of 26 (12%) nonpitching arms (P < .001). Calcifications were detected in nine of 26 (35%) pitching arms but in none of the nonpitching arms (P < .001). The average time for bilateral US was 10.4 minutes. CONCLUSION: Dynamic US provides a rapid means for evaluating,the anterior band of the UCL in professional baseball pitchers. In pitching arms, this band is thicker, is more likely to have hypoechoic foci and/or calcifications, and demonstrates more laxity with valgus stress. (C) RSNA, 2003.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 26 条
[1]
Chen F S, 2001, J Am Acad Orthop Surg, V9, P99
[2]
MEDIAL INSTABILITY OF THE ELBOW IN THROWING ATHLETES - TREATMENT BY REPAIR OR RECONSTRUCTION OF THE ULNAR COLLATERAL LIGAMENT [J].
CONWAY, JE ;
JOBE, FW ;
GLOUSMAN, RE ;
PINK, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (01) :67-83
[3]
Collateral ligaments of the elbow: Conventional MR imaging and MR arthrography with coronal oblique plane and elbow flexion [J].
Cotten, A ;
Jacobson, J ;
Brossmann, J ;
Pedowitz, R ;
Haghighi, P ;
Trudell, D ;
Resnick, D .
RADIOLOGY, 1997, 204 (03) :806-812
[4]
Medial elbow joint laxity in professional baseball pitchers - A bilateral comparison using stress radiography [J].
Ellenbecker, TS ;
Mattalino, AJ ;
Elam, EA ;
Caplinger, RA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) :420-424
[5]
Ferrara M A, 1999, JBR-BTR, V82, P222
[6]
Fritz RC, 1997, RADIOL CLIN N AM, V35, P117
[7]
FU SF, 1991, J ANAT, V175, P203
[8]
Valgus instability of the elbow in athletes [J].
Hyman, J ;
Breazeale, NM ;
Altchek, DW .
CLINICS IN SPORTS MEDICINE, 2001, 20 (01) :25-+
[9]
Indelicato P A, 1979, Am J Sports Med, V7, P72, DOI 10.1177/036354657900700114
[10]
JOBE FW, 1986, CLIN SPORT MED, V5, P621