On-line membrane preconcentration for continuous monitoring of trace pharmaceuticals

被引:19
作者
Bishop, EJ
Mitra, S
机构
[1] New Jersey Inst Technol, Dept Chem & Environm Sci, Newark, NJ 07102 USA
[2] Rutgers State Univ, Dept Chem, Newark, NJ 07102 USA
关键词
membrane extraction; pervaporation; preconcentration; chromatography; sample preparation;
D O I
10.1016/j.jpba.2004.09.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Membrane pervaporation is presented as a method for on-line concentration and monitoring of trace analytes in a simulated pharmaceutical process stream. Pervaporation involves the selective transport of volatile organics across a membrane and into a gas stream. Experiments were carried out using a polar solvent-permeable Nafion membrane and several model pharmaceutical compounds. Solvent reductions greater than 90% and enrichment factors in excess of 7.9 were observed. Residence time and temperature were found to be important operating parameters. Interaction with membrane bound sulfonic acid residues resulted in the loss of reactive analytes such as 1,2-diphenylhydrazine. The concentrated stream was monitored using HPLC and UV/vis detection. Method detection limits were 0.5-1.2 mug/mL and the relative standard deviation for six repeat injections was 3.9-6.2%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 22 条
[1]  
[Anonymous], 1992, MEMBRANE HDB
[2]  
Aptel P., 1986, SYNTHETIC MEMBRANES, P403
[3]   Hollow fiber membrane concentrator for on-line preconcentration [J].
Bishop, EJ ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :11-17
[4]   HPLC method with on-line SPE preconcentration for quantification of permethric acid sorption to goethite [J].
Bjarnholt, N ;
Svensmark, B ;
Hansen, HCB .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2004, 84 (04) :303-314
[5]  
Bungay P. M., 1986, SYNTHETIC MEMBRANES, P57, DOI DOI 10.1007/978-94-009-4712-2_3
[6]   Rapid antibiotic drug monitoring:: Meropenem and ceftazidime determination in serum and bronchial secretions by high-performance liquid chromatography-integrated sample preparation [J].
Ehrlich, M ;
Daschner, FD ;
Kümmerer, K .
JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02) :357-363
[7]   On-line membrane extraction liquid chromatography for monitoring semi-volatile organics in aqueous matrices [J].
Guo, XM ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 904 (02) :189-196
[8]   Inline gas chromatographic tracer analysis: An alternative to conventional sampling and laboratory analysis for partitioning tracer tests [J].
Jawitz, JW ;
Annable, MD ;
Clark, CJ ;
Puranik, S .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2002, 30 (04) :415-426
[9]   Pervaporation of methanol from a triglyme solution using a Nafion membrane .1. Transport studies [J].
Jiang, JS ;
Greenberg, DB ;
Fried, JR .
JOURNAL OF MEMBRANE SCIENCE, 1997, 132 (02) :255-262
[10]  
Jonsson JÅ, 2001, ADV CHROMATOGR, V41, P53