Control of ammonia and odors in animal houses by a ferroelectric plasma reactor

被引:47
作者
Zhang, RH [1 ]
Yamamoto, T [1 ]
Bundy, DS [1 ]
机构
[1] RES TRIANGLE INST,CTR ENGN & ENVIRONM TECHNOL,RES TRIANGLE PK,NC 27709
关键词
D O I
10.1109/28.485821
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this study was to develop an electric air-cleaning system for animal houses to control noxious gases and odors, An ac-powered ferroelectric packed-bed plasma reactor was tested for its ability to decompose ammonia and odors in the air. Four important parameters that affect reactor performance were investigated: gas residence time in the reactor (four test levels, 0.2 to 1.3 s), power voltage (six levels, 0 to 15 kV), power frequency (two levels, 60-Hz and 18-kHz), and initial ammonia concentration (three levels, 21, 27 and 55 ppm), Up to 95% ammonia decomposition efficiencies were obtained under a combination of test conditions, The packed-bed plasma reactor was effective in decomposing odors in the air taken from a swine house.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 9 条
[1]   AMMONIA EMISSIONS AND THEIR ROLE IN ACID DEPOSITION [J].
APSIMON, HM ;
KRUSE, M ;
BELL, JNB .
ATMOSPHERIC ENVIRONMENT, 1987, 21 (09) :1939-1946
[2]  
BARTH CL, 1984, T ASAE, V27, P859
[3]  
BUNDY DS, 1993, 1993 ASAE INT WINT M
[4]   CORONA DISCHARGE PROCESSES [J].
CHANG, JS ;
LAWLESS, PA ;
YAMAMOTO, T .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1991, 19 (06) :1152-1166
[5]  
LIU Q, 1993, C P 4 INT S LIV ENV, V4, P678
[6]  
MIZUNO A, 1988, C P I EL JPN ANN M, P327
[7]  
NEBEL C, 1976, OZONE ANAL ASPECTS O, P52
[8]   CONTROL OF VOLATILE ORGANIC-COMPOUNDS BY AN AC ENERGIZED FERROELECTRIC PELLET REACTOR AND A PULSED CORONA REACTOR [J].
YAMAMOTO, T ;
RAMANATHAN, K ;
LAWLESS, PA ;
ENSOR, DS ;
NEWSOME, JR ;
PLAKS, N ;
RAMSEY, GH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (03) :528-534
[9]  